System Specifications
| Processor |
| Number |
1 or 2 Dual-core |
| Architecture |
Type: AMD Opteron Processor 2000 Series
- Model 2210, 1.8 GHz, Dual-Core, 95W, F2 Stepping
- Model 2216, 2.4 GHz, Dual-Core, 95W, F3 Stepping
- Model 2218, 2.6 GHz, Dual-Core, 95W, F3 Stepping
- Model 2220SE, 2.8 GHz, Dual-Core, 120W, F2 Stepping
- Model 2222SE, 3.0 GHz, Dual-Core, 120W, F3 Stepping
- Model 2220, 2.8 GHz, Dual-Core, 95W, F3 Stepping
- Model 2222, 3.0 GHz, Dual-Core, 95W, F3 Stepping
- Model 2218HE, 2.6 GHz, Dual-Core, 68W, F3 Stepping
- Model 2224SE, 3.2 GHz, Dual-Core, 120W, F3 Stepping
- Model 2356, 2.3 GHz, Quad-Core, 75W, B3 Stepping
|
| Cache memory |
1 MB Level 2 cache per processor core |
|
Main Memory
|
| Capacities |
DIMM slots per processor: 4
DIMM slots per System Board: 8 (using 2 processors)
DIMM type: DDR2 667MHz Registered DIMMs (128 bit plus ECC databus)
DIMM size: 1-GB, 2-GB or 4-GB
Maximum capacity: 32 (when configured with 4-GB DIMMs and 2 processors)
NOTE: For optimal performance, install DIMMs in pairs. Pairs of DIMMs must be matched. |
|
Standard Integrated Interfaces
|
| Network |
Four 10/100/1000 Base-T Ethernet Ports |
| Network Management |
One dedicated 10/100Base-T Ethernet port |
| Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
| SAS
|
Four channel SAS interface, internal access only. |
| ATI Rage XL Video Chip, VGA Video 15-pin Port |
|
| USB |
Front: Two USB 2.0 port
Rear: Two USB 2.0 ports |
| PCI Expansion Slots |
Four internal low profile 8-lane PCI Express slots
One internal MD2 Low Profile 64-bit PCI-X slot (133 MHz) |
|
Internal Mass Storage
|
| Disks |
Up to four 2.5″ SAS internal hot-swap Disks:
- 146GB – 10000 RPM SAS
- 73GB – 10000 RPM SAS
- 73GB – 15000 RPM SAS
With or Without DVD/CD-RW: 4 disks are supported.
|
| DVD-ROM |
One EIDE DVD-ROM or CD-RW Writer (optional) |
|
Power Supplies
|
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 550W)
(UL Maximum AC input = 550W x 1.33 efficiency = 733W)
(Typical power consumption: 450W) |
|
Environment
|
| AC power |
90-264 V AC (47-63 Hz) |
| DC Power |
-48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3 A at -60 V DC) |
| Temperature |
Single, non-rack system:
Operating: 10° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F) |
| Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb |
| Altitude |
Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
| Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
8.0 B at or below 25° C
8.4 B at max ambient
LpAm bystander
64dB at or below 25° C
69dB at max ambient |
Regulations
Meets or exceeds the following requirements:
|
| RoHS Compliance Level |
RoHS:YL |
| Safety |
IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences |
| RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.32, ICES-003 |
| Immunity |
EN55024, EN300-386:v1.31 |
| Certifications |
Safety: cULus Mark, UL Demco GS Mark, CE Mark, CCC, GOST R, S-Mark
EMC: CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels: FCC, VCCI, BSMI, C-tick, MIC, CCC, GOST R |
|
Dimensions and Weight
|
| Height |
87.6 mm (3.44 in.) |
| Width |
445 mm (17.5 in.) |
| Depth |
632 mm (24.8 in.) |
| Weight |
25.5 kg (56.2 lb.) |
|
Rack Mounting
|
| Optional Slide Rail Kit (X8029A)2is a 4-point mounted slide rail kit. |
|