Processor | |
Number | 1 Quad-Core |
Architecture | Type: AMD Opteron Quad-Core Processor |
CPUs | AMD 1.9GHz Quad-Core Opteron 2347 HE |
Cache memory | 2x512KB Level 2 and 1MB Level 3 for Quad-Core |
Main Memory | |
Capacities |
Total DIMM slots: 16 slots on the system board (12 slots are not populated) DIMM type: PC2-5300 DDR2 667MHz Registered DIMMs (128 bit plus ECC databus) DIMM size: 2-GB Maximum capacity: 8GB (when configured with 2-GB DIMMs) NOTE: All DIMMs must be the same density. Slots D4,D5,D6, and D7 are populated in the 4 x 2GB configuration. |
Standard Integrated Interfaces | |
Network | Four 10/100/1000 Base-T Ethernet Ports |
Network Management | One dedicated 10/100Base-T Ethernet port |
Serial Management | One dedicated TIA/EIA-232-F asynchronous RJ45 port |
SAS | Four channel SAS interface, internal access only. |
USB |
Front: Two USB 2.0 ports Rear: Two USB 2.0 ports Internal: One USB 2.0 port |
PCI Expansion Slots | Six internal MD2 low profile 8-lane PCI Express slots (1x 16-lane, 4x 8-lane, 1x 4-lane) |
Internal Mass Storage | |
Disks | SAS: 16 x 2.5″ 146GB or 300GB – 10000 RPM SAS Disks |
Power Supplies | |
Dual redundant, hot swappable power supplies (Power supply rating DC output = 1050W) (UL Maximum AC input = 1050W x 1.33 efficiency = 1397W) (12 Amps RMS at 100 VAC) |
|
Software | |
Features |
|
Environment | |
AC power | 100-200/200-240 V AC (50-60 Hz) |
Temperature | Single, non-rack system: Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -40° C to 65° C (-40° F to 149° F) |
Humidity | Single, non-rack system: Operating: 10% to 90% relative humidity noncondensing, 38° C (100.4° F) max wet bulb Nonoperating: up to 93% relative humidity noncondensing |
Altitude | Single, non-rack system: Operating: up to 3000 m (9843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise | Single, non-rack system: LwAd (1B=10dB) 6.8 B at max ambient LpAm bystander 53 dB at max ambient |
Regulations Meets or exceeds the following requirements: |
|
RoHS Compliance Level | RoHS:YL |
Safety | IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences |
RFI/EMI | FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386 |
Immunity | EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A |
Dimensions and Weight | |
Height | 88 mm (3.49 in.) |
Width | 426 mm (16.75 in.) |
Depth (not including PSU handle) | 714 mm (28.125 in.) |
Depth (including PSU handle) | 736.4 mm (28.99 in.) |
Weight | 25.75 kg (56.77 lb.) maximum assuming PCI-Express card weighs 0.12 kg (0.25 lb) each, and without the rack mounting slide rail kit installed. |
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 150-4277 | 3V Lithium coin battery, RoHS:Y |
CPU Module | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6307A | 1.9GHz Quad-Core AMD Opteron 2347HE, RoHS:Y | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4095 | 1.9 GHz CPU, Opteron 2347HE Quad Core, B3 Stepping, 55W, RoHS:Y | |||
n/a | 371-4679 | 2.2 GHz CPU, Opteron 2427 6-Core, D0 Stepping, 75W, RoHS:Y |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X311L | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-1097 | IEC 320 C13 to NEMA 5-15P – 15A/125V 2.5M Black, RoHS:Y | |||
X312E | Localized Power Code Kit – China, RoHS:Y | |||
180-1982 | IEC 320 C13 to GB 2099/GB 1002 – 10A/250V 2.5M, RoHS:Y | |||
X312F | Localized Power Cord Kit – Argentina, RoHS:Y | |||
180-1999 | IEC 320 C13 to IRAM 2073 – 10A/250V 2.5M Black, RoHS:Y | |||
X312G | Localized Power Cord Kit – Korea, RoHS:Y | |||
180-1662 | IEC 320 C13 to KSC 8305 – 15A/250V 2.5M Black, RoHS:Y | |||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X332A | Localized Power Cord Kit – Taiwan, RoHS:Y | |||
180-2121 | IEC 320 C13 to NEMA 5-15P – 10A/125V 2.5M Black, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4237A | 375-3606 | Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express, RoHS:Y |
Disk Backplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7760 | 16-Slot Disk Backplane, PATA DVD, RoHS:YL | ||
n/a | 542-0355 | Backplane Retainer Clip Kit | ||
|
|
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
XRA-SS2CF-146G10K | 540-7355 | 146GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-7868 | 146GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-7869 | 300GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1027A-Z | 501-7283 | PCI Express Dual 10-Gigabit Ethernet Fiber, RoHS:Y | ||
X4446A-Z | 375-3481 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
X5558A | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
X5560A-Z | 375-3495 | 10Gb/sec XFP Optical Transceiver Long Range (LR), RoHS:Y | ||
X7280A-2 | 371-0905 | PCI Express Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7281A-2 | 371-0904 | PCI Express Dual Gigabit Ethernet MMF, RoHS:Y |
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2211 | Fan Power Board, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2940 | CPU Dual Fan Assembly w/ Metal Fingerguards, RoHS:Y | ||
|
|
|||
n/a | 541-3290 | CPU Dual Fan Assembly w/ Metal Fingerguards, RoHS:Y | ||
|
|
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIE2FC-QF4 | 375-3356 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF8-Z | 371-4325 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2109 | x8/x8 XAUI Riser Card Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2299 | x16/x4 Riser, RoHS:Y |
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6321A | 540-7599 | 4GB (2 × 2GB) Memory FRU, RoHS:Y | ||
|
|
|||
X6321A-C | 540-7829 | 4GB (2 × 2GB) Memory FRU | ||
|
|
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6328A | 300-1897 | 1050 Watt Power Supply, Type A217, RoHS:Y | ||
n/a | 541-2073 | Power Distribution Board/Bus Bar Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6324A | 371-2742 | Cable Management Arm, RoHS:Y | ||
X6325A | 371-2740 | Snap-In Slide Rail Rackmount Kit, 730mm, RoHS:Y | ||
X6326A | 371-2741 | Screw-Mount Slide Rail Rackmount Kit, 730mm, RoHS:Y |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2732 | USB Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIE2SCSIU320Z | 375-3357 | Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y | ||
SG-XPCIE8SAS-I-Z | 371-3255 | PCI Express 8-Port SAS Controller, RoHS:Y |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.