Processor | |
Number | 1 or 2 Dual-Core or Quad-Core |
Architecture | Type: AMD Opteron Dual-Core or Quad-Core Processors |
CPUs | AMD 2.6GHz Dual-Core Opteron 2218HE AMD 3.0GHz Dual-Core Opteron 2222, 95W AMD 2.3GHz Quad-Core Opteron 2356, 75W AMD 2.5GHz Quad-Core Opteron 2380, 75W AMD 2.7GHz Quad-Core Opteron 2384, 75W AMD 2.3GHz Quad-Core Opteron 2376HE, 55W AMD 2.2GHz 6-Core Opteron 2427, 75W AMD 2.4GHz 6-Core Opteron 2431, 75W AMD 2.6GHz 6-Core Opteron 2435, 75W |
Cache memory | 2x1MB Level 2 for Dual-Core 4x512KB Level 2 for Quad-Core |
Main Memory | |
Capacities |
Total DIMM slots: 16 DIMM type: PC2-5300 DDR2 667MHz Registered DIMMs (128 bit plus ECC databus) DIMM size: 1-GB, 2-GB, 4-GB or 8-GB Maximum capacity: 128GB (when configured with 8-GB DIMMs) NOTE: DIMMs must be installed in pairs. Pairs of different densities may be mixed. |
Standard Integrated Interfaces | |
Network | Four 10/100/1000 Base-T Ethernet Ports |
Network Management | One dedicated 10/100Base-T Ethernet port |
Serial Management | One dedicated TIA/EIA-232-F asynchronous RJ45 port |
SAS | SAS support via SAS Host Bus Adapter (HBA). |
USB |
Front: Two USB 2.0 ports Rear: Two USB 2.0 ports Internal: One USB 2.0 port |
PCI Expansion Slots | Three internal MD2 low profile 8-lane PCI Express slots (all with x16 mechanical connectors) |
Internal Mass Storage | |
Disks |
SAS: Up to eight 2.5″ SAS Disks with add-on SAS Host Bus Adapter (146GB – 10000 RPM SAS, 73GB 10000 RPM SAS, or 73GB 15000 RPM SAS) |
Solid State Drives | Up to eight 32GB solid state drives |
DVD-ROM | One EIDE DVD+/-RW drive |
Power Supplies | |
Dual redundant, hot swappable power supplies (Power supply rating DC output = 658W) (UL Maximum AC input = 658W x 1.33 efficiency = 875W) (8.2 Amps RMS at 100 VAC) |
|
Environment | |
AC power | 100-200 V / 200-240 V AC (50-60 Hz) |
Temperature | Single, non-rack system: Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -40° C to 65° C (-40° F to 149° F) |
Humidity | Single, non-rack system: Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb |
Altitude | Single, non-rack system: Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise | Single, non-rack system: LwAd (1B=10dB) 6.6 dB at max ambient LpAm bystander 51 dB at max ambient |
Regulations Meets or exceeds the following requirements: |
|
RoHS Compliance Level | RoHS:YL |
Safety | IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences |
RFI/EMI | FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386 |
Immunity | EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A |
Dimensions and Weight | |
Height | 44 mm (1.73 in.) |
Width (not including ears) | 425.5 mm (16.75 in.) |
Width (including ears) | 443.9 mm (17.47 in.) |
Depth (not including PSU handle) | 711.2 mm (28 in.) |
Depth (including PSU handle) | 736.4 mm (28.99 in.) |
Weight | 18.55 kg (40.90 lb.) maximum assuming PCI-Express card weighs 0.12 kg (0.25 lb) each, and without the rack mounting slide rail kit installed. |
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 150-4277 | 3V Lithium coin battery, RoHS:Y |
CPU Module | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
6335A | Single Processor HyperTransport Terminator, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-2481 | HyperTransport Termination Adapter, RoHS:Y | |||
X5392A | 2.2GHz 6-Core AMD Opteron 2427, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4679 | 2.2 GHz CPU, Opteron 2427 6-Core, D0 Stepping, 75W, RoHS:Y | |||
X8254A | 2.7GHz AMD Quad Core Opteron 2384, RoHS:Y | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4438 | 2.7 GHz CPU, Opteron 2384 Quad Core, C2 Stepping, 75W, RoHS:Y | |||
X4285A | 540-7602 | HyperTransport Bridge Card & Risers for Quad Core CPU, RoHS:Y | ||
|
|
|||
|
|
|||
X5352A | 2.9GHz Quad-Core AMD Opteron 2389, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4641 | 2.9 GHz CPU, Opteron 2389 Quad Core, C2 Stepping, 75W, RoHS:Y | |||
X5380A | 2.1GHz 6-Core AMD Opteron 2425 HE, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4678 | 2.1GHz CPU, Opteron 2425 HE 6-Core, D0 Stepping, 55W, RoHS:Y | |||
X5381A | 2.4GHz 6-Core AMD Opteron 2431, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4680 | 2.4 GHz CPU, Opteron 2431 6-Core, D0 Stepping, 75W, RoHS:Y | |||
X5382A | 2.6GHz 6-Core AMD Opteron 2435, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4681 | 2.6 GHz CPU, Opteron 2435 6-Core, D0 Stepping, 75W, RoHS:Y | |||
X6300A | 2.6GHz Dual-Core AMD Opteron 2218HE, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-2684 | 2.6GHz AMD Dual Core Opteron 2218HE, F3 Stepping, 68W, RoHS:YL | |||
X6301A | 3.0GHz Dual-Core AMD Opteron 2222, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-2502 | 3.0 GHz CPU, Opteron 2222 Dual Core, F3 Stepping, 95W, RoHS:Y | |||
X6305A | 2.3GHz Quad-Core AMD Opteron 2356, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4042 | 2.3 GHz CPU, Opteron 2356 Quad Core, B3 Stepping, 75W, RoHS:Y | |||
X6307A | 1.9GHz Quad-Core AMD Opteron 2347HE, RoHS:Y | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4095 | 1.9 GHz CPU, Opteron 2347HE Quad Core, B3 Stepping, 55W, RoHS:Y | |||
X8252A | 2.3 GHz CPU, Opteron 2376HE Quad Core, 55W, RoHS:YL | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4502 | 2.3 GHz CPU, Opteron 2376 HE Quad Core, C2 Stepping, 55W, RoHS:Y | |||
X8253A | 2.5GHz Quad-Core AMD Opteron 2380, RoHS:Y | |||
310-0128 | Opteron Heatsink, RoHS:Y | |||
371-4432 | 2.5 GHz CPU, Opteron 2380 Quad Core, C2 Stepping, 75W, RoHS:Y | |||
n/a | 310-0180 | Opteron Heatsink, RoHS:Y |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X311L | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-1097 | IEC 320 C13 to NEMA 5-15P – 15A/125V 2.5M Black, RoHS:Y | |||
X312E | Localized Power Code Kit – China, RoHS:Y | |||
180-1982 | IEC 320 C13 to GB 2099/GB 1002 – 10A/250V 2.5M, RoHS:Y | |||
X312F | Localized Power Cord Kit – Argentina, RoHS:Y | |||
180-1999 | IEC 320 C13 to IRAM 2073 – 10A/250V 2.5M Black, RoHS:Y | |||
X312G | Localized Power Cord Kit – Korea, RoHS:Y | |||
180-1662 | IEC 320 C13 to KSC 8305 – 15A/250V 2.5M Black, RoHS:Y | |||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X332A | Localized Power Cord Kit – Taiwan, RoHS:Y | |||
180-2121 | IEC 320 C13 to NEMA 5-15P – 10A/125V 2.5M Black, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
4280A | 596-7335 | Internal SAS Cable Option, RoHS:Y | ||
|
|
|||
|
|
|||
4281A | 596-7336 | Internal SATA Cable Option, RoHS:Y | ||
|
|
|||
|
|
|||
n/a | F540-7609 | SAS/SATA Cable Kit, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6000A | 375-3424 | PCI Express Sun Crypto Accelerator 6000, RoHS:Y | ||
X1236A-Z | 375-3382 | Dual Port 10Gb/sec 4x PCI Express Infiniband Host Channel Adapter – Low Profile, RoHS:Y | ||
X4217A-Z | 375-3549 | Dual Port 20Gb/sec 4x PCI Express Infiniband Host Channel Adapter – Low Profile, RoHS:Y |
Disk Backplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7797 | 8-Slot Disk Backplane, PATA DVD, RoHS:Y | ||
n/a | 542-0355 | Backplane Retainer Clip Kit | ||
|
|
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
XRA-SS2CF-300G10K | 540-7869 | 300GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
XRA-ST2CF-32G2SSD | 540-7841 | 32GB Solid State Drive Assembly, SATA Interface, RoHS:Y | ||
|
|
|||
|
|
|||
XRB-SS2CF-146G10K | 540-7868 | 146GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SS2CF-146G10K | 540-7355 | 146GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SS2CF-73G10K | 540-7354 | 73GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SS2CF-73G15K | 540-7361 | 73GB – 15000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIEFCOE2-Q-SR | 375-3681 | Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA – SR, RoHS:Y | ||
SG-XPCIEFCOE2-Q-TA | 375-3682 | Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA – Direct Attach, RoHS:Y | ||
X1027A-Z | 501-7283 | PCI Express Dual 10-Gigabit Ethernet Fiber, RoHS:Y | ||
X1106A-Z | 375-3585 | Intel PRO/10GbE-SR x8 PCI Express Low Profile Bracket, RoHS:Y | ||
X1107A-Z | 375-3586 | Intel PRO/10GbE-SR x8 PCI Express Low Profile Bracket, RoHS:Y | ||
X4446A-Z | 375-3481 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
X4447A-Z | 511-1422 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
560-2884 | Ship Kit for Gigabit Ethernet options | |||
|
|
|||
X5558A | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
X5560A-Z | 375-3495 | 10Gb/sec XFP Optical Transceiver Long Range (LR), RoHS:Y | ||
X7280A-2 | 371-0905 | PCI Express Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7281A-2 | 371-0904 | PCI Express Dual Gigabit Ethernet MMF, RoHS:Y | ||
n/a | 501-7606 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
|
|
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2112 | Fan Power Board, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2802 | Fan Module, RoHS:Y | ||
|
|
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIE1FC-EM4 | 375-3396 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-EM8-Z | 371-4295 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF4 | 375-3355 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF8-Z | 371-4324 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM4 | 375-3397 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM8-Z | 371-4306 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF4 | 375-3356 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF8-Z | 371-4325 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2128 | x8 PCI Express/XAUI Riser Card Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
n/a | 541-2298 | 1-Slot x16 PCI Express Riser Assembly, RoHS:Y | ||
|
|
|||
|
|
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4287A | 541-3419 | 16GB (2 × 8GB DDR2-667 Registered ECC dual-rank DIMMs) | ||
|
|
|||
X6322A | 540-7600 | 8GB (2 × 4GB) Memory FRU, RoHS:Y | ||
|
|
|||
X6320A | 540-7598 | 2GB (2 × 1GB) Memory FRU, RoHS:Y | ||
|
|
|||
X6321A | 540-7599 | 4GB (2 × 2GB) Memory FRU, RoHS:Y | ||
|
|
|||
X6321A-C | 540-7829 | 4GB (2 × 2GB) Memory FRU | ||
|
|
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6327A | 300-2015 | 658 Watt AC Power Supply, Type A221, RoHS:Y | ||
n/a | 501-7696 | Power Distribution Board, RoHS:Y |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6324A | 371-2742 | Cable Management Arm, RoHS:Y | ||
X6325A | 371-2740 | Snap-In Slide Rail Rackmount Kit, 730mm, RoHS:Y | ||
X6326A | 371-2741 | Screw-Mount Slide Rail Rackmount Kit, 730mm, RoHS:Y |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6323A | 541-2110 | PATA DVD-Writer/CD-Writer – USB Board Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2732 | USB Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIE2SCSIU320Z | 375-3357 | Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y | ||
SG-XPCIE8SAS-E-Z | 375-3487 | PCI Express 8-Port Host Adapter, RoHS:Y | ||
SG-XPCIE8SAS-I-Z | 371-3255 | PCI Express 8-Port SAS Controller, RoHS:Y | ||
SGXPCIESAS-R-EXT-Z | 371-3253 | Lithium Ion Battery Module | ||
375-3537 | 8-Port SAS RAID External HBA, RoHS:Y | |||
SGXPCIESAS-R-INT-Z | 371-3253 | Lithium Ion Battery Module | ||
375-3536 | 8-Port SAS Adaptec RAID HBA, RoHS:Y |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.