Processor | |
Number | Up to eight |
Architecture | 1.2GHz or 1.35GHz UltraSPARC[tm] IV, 1.5GHz, or 1.8GHz UltraSPARC IV+ |
Cache memory | 64-KB data and 32-KB instruction per pipeline
Secondary: 16-MB external (8-MB per pipeline), 2-MB on chip L2 cache |
Main Memory | |
Capacities | Total of 16 DIMM memory slots available per CPU/Memory board
512MB, 1GB, or 2GB (32GB maximum per CPU/Memory board, 128GB maximum when configured with 8 processors) Note: Install DIMMs in groups of four. |
Standard Interfaces | |
Ethernet |
|
Keyboard and mouse | USB (uses one of the two standard USB (Type A) port) |
PCI | PCI slots are hot-pluggable
|
Remote System Controller |
|
Serial | Two EIA-232D/EIA-423 serial ports (DB25) via splitter cable (X985A) |
USB | Two USB 1.0 ports |
Internal Mass Storage | |
Disks | Up to 12 3.5″ × 1″ 10000 RPM FC-AL disks, 73GB and 146GB capacity. Maximum total capacity of 1.75TB. |
DVD-ROM | 16X ATAPI DVD-ROM Drive |
Tape | Optional 12GB DDS3 4mm, 20GB DDS4 4mm SCSI drive, or 4mm DAT 72 SCSI Tape |
Power Supplies | |
Type | 2 minimum, 3 for N+1 redundancy, individual power cords |
Output | 1629W maximum per power supply |
Environment | |
AC Power | 200-240 VAC, 47-63 Hz, 2078VA |
Input power | 3200 W (max) |
Leakage Current | 3.5mA (max) |
Heat output | 10,912 BTU/hr (max) |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing; 27° C max wet bulb Nonoperating: 95% relative humidity, noncondensing at 40° C |
Altitude |
Operating: 0 to 3000 m (0 to 10,000 ft.) Nonoperating: 0 to 12,000 m (0 to 40,000 ft.) |
Acoustic noise |
Operating: 66.5 dBA ok prompt: 75.7 dBA |
Vibration |
Operating: 0.0002 G2/Hz, 5 – 500 Hz (random) (deskside) 0.00015 G2/Hz, 5 – 500 Hz (random) (rackmounted) Nonoperating: 0.002 G2/Hz, 5 – 500 Hz (random) (deskside) 0.0015 G2/Hz, 5 – 500 Hz (random) (rackmounted) |
Shock |
Operating: 4 G peak, 11 milliseconds half-sine pulse (deskside) 3 G peak, 11 milliseconds half-sine pulse (rackmounted) Nonoperating: 15 G peak, 11 milliseconds half-sine pulse (deskside) 10 G peak, 11 milliseconds half-sine pulse (rackmounted) |
Handling Drops | 50 mm |
Threshold Impact | 1 m/s |
Number of cords | 3 |
Regulations Meets or exceeds the following requirements: |
|
Safety | UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part1040, CNS14336 |
Ergonomics | EK1-ITB-2000 |
RFI/EMI | EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3 |
Immunity | EN55024/CISPR24 |
Regulatory Markings | CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark |
Telecommunications | EN300-386 |
X-ray | US DHHS 21 CFR Subchapter J, PTB German X-ray Decree |
Dimensions and Weights | |
Height1 | 71.4 cm (28.1 in.) with castors 70.0 cm (27.6 in.) without castors |
Width | 48.0 cm (18.9 in.) |
Depth | 83.6 cm (32.9 in.) |
Weight | 88.0 kg (194.0 lb.)(minimum, approximate) 130.6 kg (288.0 lb.)(maximum, approximate) |
Power Cord | 2.5 m (8.2 ft.) |
Backplane/Centerplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6885A-Z | 594-3779 | Storage Expansion Kit, includes a backplane, cables and 6 of the following disks:, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
X7858A-Z | 594-3315 | FC-AL Backplane Assembly – no disk drives, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 530-3731 | 70cm FC-AL Cable 6-11 C/D to 0-5 F/E, RoHS:Y |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 Buy | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 Buy | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X320A Buy | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-2164 | IEC 320 C13 to NEMA 6-15P – 10A/250V 2.0M Black, RoHS:Y | |||
X332T | International Power Cord Kit, RoHS:Y | |||
180-2071 | Blue 16A IEC 309 to IEC 320 C13 International 4.0M, RoHS:Y | |||
X340L Buy | Power Kit for North America, L6-20 20A Twist Lock Plug, RoHS:Y | |||
180-2070 | NEMA L6-20P to IEC 320 C13 – 4.0M, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
X336L | U.S. Power Cords 4-Pack, RoHS:Y | |||
180-2070 Buy | NEMA L6-20P to IEC 320 C13 – 4.0M, RoHS:Y | |||
X337L | International Power Cords 4-Pack, RoHS:Y | |||
180-2071 | Blue 16A IEC 309 to IEC 320 C13 International 4.0M, RoHS:Y | |||
X338L | U.S. Watertight Power Cords 4-Pack, RoHS:Y | |||
180-2072 | Blue 20A Watertight IEC 309 to IEC 320 C13, 4.0M, RoHS:Y | |||
X339L | International Watertight Power Cords 4-Pack, RoHS:Y | |||
180-2073 | Blue 16A Watertight IEC 309 to IEC 320 C13 4.0M, RoHS:Y | |||
n/a | 530-3594 | Serial Port Adapter (Y-Splitter) Cable, 50 cm, RoHS:Y | ||
n/a | 530-3730 | 35cm FC-AL Cable 6-11 A/B ro 0-5 F/E, RoHS:Y | ||
n/a | 530-3774 | Disk 6-11 Power and ID Cable, RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7314 | Advanced Lights Out Management (ALOM) Plus Card, RoHS:YL |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
XRA-FC1CB-146G15KZ | 540-6487 Buy | 146GB – 15000 RPM FC-AL, Disk Assembly with one of the following disks:, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4445A Buy | 501-6738 | Quad GigaSwift PCI-X Ethernet (QGE-X), RoHS:Y | ||
X7285A Buy | 371-0911 | Low Profile PCI-X Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7286A | 371-0912 Buy | Low Profile PCI-X Single Gigabit Ethernet MMF, RoHS:Y |
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-1076 | PCI I/O Fan Tray. RoHS:Y | ||
n/a | 541-1081 | 80MM Motherboard Fan Assembly, RoHS:Y | ||
n/a | 541-1106 | CPU Fan Tray, RoHS:Y |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z Buy | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 Buy | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM4-Z Buy | 375-3399 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 Buy | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-EM2 | 375-3304 Buy | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QL2 | 375-3383 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM2 | 375-3305 Buy | 2Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF2-Z | 375-3363 | 2Gb PCI Dual FC Host Adapter, RoHS:Y | ||
|
|
|||
X6727A | 375-3030 | PCI Dual FC Host Adapter+, RoHS:YL |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7707 Buy | I/O Board, RoHS:YL |
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7051A-Z | 2 GB (4 × 512MB SDRAM DIMMs), RoHS:YL | |||
501-7385 Buy | 512MB SDRAM DIMM, RoHS:YL | |||
X7056A-Z | 4 GB (4 × 1GB SDRAM DIMMs), RoHS:YL | |||
501-7386 | 1GB SDRAM DIMM, RoHS:YL | |||
X7058A-Z | 8 GB (4 × 2GB SDRAM DIMMs), RoHS:YL | |||
540-6489 | 2GB SDRAM DIMM Assembly, RoHS:YL | |||
|
|
|||
F511-1030 | Package of 25 × 512MB SDRAM DIMMs | |||
|
|
|||
F511-1031 | Package of 25 × 1GB SDRAM DIMMs | |||
|
|
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 300-2017 Buy | 220V Power Supply – Type A186, RoHS:YL | ||
n/a | 375-3480 Buy | Power Distribution Board, RoHS:YL |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X9628A-Z | 594-3317 | Rack Mount Kit, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
X9638A-Z | 594-3821 | Rack Mount Kit for Sun Rack 900, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XTAPDAT72-5F-2 | 380-1324 | DAT 72 Internal Tape Drive, 5.25 inch/68 pin SCSI, RoHS:Y | ||
n/a | 541-2478 | DVD-ROM Assembly, RoHS:YL | ||
|
|
System Board | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7227 | Motherboard, RoHS:YL | ||
n/a | 501-7713 | CPU/Memory Board w/2 × USIV+ 2.1GHz, 0MB, RoHS:YL |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.