• 64-bit Chip Multithreading (CMT) UltraSPARC® IV technology, with over 2x the throughput of previous generations • Scales up to 4 x 1.35-GHz UltraSPARC IV CPUs with 16 MB L2 cache per processor
• Up to 8 simultaneous compute threads with up to 32 GB memory • SolarisTM 8, Solaris 9, and Solaris 10 Operating System
• Robust capabilities in the Solaris 10 OS such as Predictive Self-Healing to increase reliability, Solaris Containers for increased utilization, and dTrace to optimize application performance • Industry leading price/performance and benchmarks
• 2 FC-AL disk drives, multipathing-ready • 9.6-GB/second SunTM Fireplane interconnect
• N+1 hot-swap power supplies/ hot-pluggable disks • Sun Systems Controller for remote system administration • Automatic System Recovery to maximize uptime • 6 PCI slots help ensure a highly expandable system
• 5-RU, rack-optimized enclosure
Processor | |
Number | Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs) |
Architecture | 1.35GHz UltraSPARC[tm] IV, 1.5GHz, or 1.8GHZ UltraSPARC IV+ |
Cache memory | Cache (L1): 64-KB data and 32-KB instruction per pipeline Secondary (L2): 16 MB external (8 MB per pipeline), 2 MB on chip L2 cache Cache (L3): 32 MB external off-chip (UltraSPARC IV+ processor) |
Main Memory | |
Capacities | 8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board512MB, 1GB, or 2GB expansion (32GB maximum per CPU/Memory board, 64GB maximum when configured with 4 processors) All memory DIMM slots must be fully populated. |
Standard Interfaces | |
Ethernet | Two 10/100/1000-Mbps Ethernet |
Keyboard and mouse | USB |
PCI | Six PCI slots compliant with PCI specification Revision 2.1:
Note: PCI slots 0, 1, and 2 are full length card slots (12 inch); PCI slots 3, 4, and 5 are short length card slots (7 inch). |
Remote System Controller | One ALOM Plus card plugs into a dedicated slot on the system I/O board |
Serial | One RJ45 serial port |
USB | Two (compliant with USB Revision 1.1) |
Internal Mass Storage | |
Disks | Two front-accessible, hot-pluggable, FC-AL disks, 73GB or 146GB, 3.5-in. x 1.0-in. 10,000 RPM, or 146GB 15,000 RPM, maximum total capacity of 292 GB |
DVD-ROM | 8X Slimline DVD-ROM / 24X CD-ROM drive |
Power Supplies | |
Type | One required, two for redundancy fitted as standard, each with independent power cord |
Output | 1448 W per power supply |
Environment | |
AC Power | Auto Ranging 200-240 VAC, 50 or 60 Hz, 8A @ 200-240 VAC |
Input power | 1052 W (max measured), 1600 W (mfg rating) |
Heat output | 3590 BTU/hr (max measured), 5460 BTU/hr (mfg rating) |
Temperature |
Operating: 5° C to 35°C (41°F to 95°F) Nonoperating: -20°C to 60°C (-4°F to 140°F) |
Humidity |
Operating: 20% to 80% RH noncondensing; 27°C (81°F) wet bulb Nonoperating: 95% RH noncondensing |
Altitude |
Operating: 0 to 3000 meters (0 to 10,000 feet) Nonoperating: 0 to 12,000 meters (0 to 40,000 feet) |
Acoustic noise |
Operating: 74.5 dBA Idling: 74.5 dBA |
Vibration |
Operating: .0001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz Nonoperating: .001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz |
Shock |
Operating: 3g peak, 11 milliseconds half-sine pulse Nonoperating: 10g peak, 11 milliseconds half-sine pulse |
Handling Drops | 25 mm (10 in) |
Threshold Impact | 1 meter/second |
Number of cords | 2 |
Regulations Meets or exceeds the following requirements: |
|
RoHS Compliance Level | RoHS:YL |
Safety | UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part1040, CNS14336 |
Ergonomics | EK1-ITB-2000 |
RFI/EMI | EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3 |
Immunity | EN55024/CISPR24 |
Regulatory Markings | CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark |
Telecommunications | EN300-386 |
X-ray | DHHS 21 Subchapter J; PTB German X-ray Decree |
Dimensions and Weights | |
Height | 222 mm (8.75 in) |
Width | 446 mm (17.5 in) |
Depth | 610 mm (24 in) |
Weight | Min 35.83 kg (79 lbs) Max 44 kg (97 lbs) |
Power Cord | 2.5 m (8.2 ft) |
Backplane/Centerplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7224 | Centerplane, RoHS:YL | ||
n/a | 501-7322 | FC-AL Backplane Assembly, RoHS:YL | ||
|
|
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 150-2850 | 3V Lithium Battery BR1632 / CR1632, RoHS:Y |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X320A | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-2164 | IEC 320 C13 to NEMA 6-15P – 10A/250V 2.0M Black, RoHS:Y | |||
X332T | International Power Cord Kit, RoHS:Y | |||
180-2071 | Blue 16A IEC 309 to IEC 320 C13 International 4.0M, RoHS:Y | |||
X333A-25-10-IL | Localized Power Cord Kit Israel, RoHS:Y | |||
180-2130 | IEC 320 C13 to SI-32, 10A/250V, 2.5M, Black, RoHS:Y | |||
X340L | Power Kit for North America, L6-20 20A Twist Lock Plug, RoHS:Y | |||
180-2070 | NEMA L6-20P to IEC 320 C13 – 4.0M, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
X336L | U.S. Power Cords 4-Pack, RoHS:Y | |||
180-2070 | NEMA L6-20P to IEC 320 C13 – 4.0M, RoHS:Y | |||
X337L | International Power Cords 4-Pack, RoHS:Y | |||
180-2071 | Blue 16A IEC 309 to IEC 320 C13 International 4.0M, RoHS:Y | |||
X338L | U.S. Watertight Power Cords 4-Pack, RoHS:Y | |||
180-2072 | Blue 20A Watertight IEC 309 to IEC 320 C13, 4.0M, RoHS:Y | |||
X339L | International Watertight Power Cords 4-Pack, RoHS:Y | |||
180-2073 | Blue 16A Watertight IEC 309 to IEC 320 C13 4.0M, RoHS:Y | |||
X9713A-Z | 530-4253 | Loop-B FC-AL Cable, RoHS:Y | ||
n/a | 530-1351 | IEC 320 C13 to NEMA 6-15 – 10A/250V 2.0M Black, RoHS:Y | ||
n/a | 530-3710 | FC-AL Backplane Data Cable, RoHS:Y | ||
n/a | 530-3719 | FC-AL Backplane Power Cable, RoHS:Y | ||
n/a | 530-3765 | Loop-B FC-AL Cable, RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1355A-2 | 371-0982 | 2M, 80-Pin, 4-Port, DB37, RS449 Breakout Cable,RoHS:Y | ||
375-3296 | Quad Port High Speed Serial Interface PCI-X (HSI/U), RoHS:Y | |||
X1333A-4 | 375-3418 | Infiniband PCI-X Card, RoHS:YL | ||
n/a | 501-7314 | Advanced Lights Out Management (ALOM) Plus Card, RoHS:YL |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6805A | 540-6604 | 73.4GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-FC1CB-146G10K | 540-6605 | 146GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-FC1CB-146G15KZ | 540-6487 | 146GB – 15000 RPM FC-AL, Disk Assembly with one of the following disks:, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4150A-2 | 501-7415 | GigaSwift Ethernet UTP (GCS), RoHS:Y | ||
X4445A | 501-6738 | Quad GigaSwift PCI-X Ethernet (QGE-X), RoHS:Y | ||
X5544A-4 | 10Gb PCI-X Ethernet Adapter, no transceiver, RoHS:Y | |||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
X5558A | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
X5560A-Z | 375-3495 | 10Gb/sec XFP Optical Transceiver Long Range (LR), RoHS:Y | ||
X7285A | 371-0911 | Low Profile PCI-X Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7286A | 371-0912 | Low Profile PCI-X Single Gigabit Ethernet MMF, RoHS:Y | ||
4455A-4 | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
501-7414 | 10Gb/sec PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
4466A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL | ||
501-7414 | 10Gb/sec PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
5544A-4 | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
6644A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL | ||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
X5559A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL |
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-1120 | PCI Fan Tray, RoHS:Y | ||
n/a | 541-1256 | CPU Fan Tray, RoHS:YL |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM4-Z | 375-3399 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-EM2 | 375-3304 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QL2 | 375-3383 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM2 | 375-3305 | 2Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF2-Z | 375-3363 | 2Gb PCI Dual FC Host Adapter, RoHS:Y | ||
|
|
|||
X6727A | 375-3030 | PCI Dual FC Host Adapter+, RoHS:YL |
Graphics | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7296A | 375-3290 | XVR-100 Graphics Accelerator (64MB), RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7315 | PCI I/O Riser Board, RoHS:YL | ||
|
|
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7051A-Z | 2 GB (4 × 512MB SDRAM DIMMs), RoHS:YL | |||
501-7385 | 512MB SDRAM DIMM, RoHS:YL | |||
X7056A-Z | 4 GB (4 × 1GB SDRAM DIMMs), RoHS:YL | |||
501-7386 | 1GB SDRAM DIMM, RoHS:YL | |||
X7058A-Z | 8 GB (4 × 2GB SDRAM DIMMs), RoHS:YL | |||
540-6489 | 2GB SDRAM DIMM Assembly, RoHS:YL | |||
|
|
|||
F511-1030 | Package of 25 × 512MB SDRAM DIMMs | |||
|
|
|||
F511-1031 | Package of 25 × 1GB SDRAM DIMMs | |||
|
|
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 300-1987 | 1448W Power Supply, RoHS:YL | ||
n/a | 375-3168 | Power Distribution Board, RoHS:YL |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-4427 | 4-Post Rack Kit (370-4427-02 = 27″) – discontinued June 2002 (370-4427-03 = 25″) – obsolete (370-4427-04 = 25″) – add slide kit, RoHS:YL |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 371-1789 | Slimline 8X DVD-ROM / 24X CD-ROM, RoHS:Y | ||
n/a | 390-0289 | Slimline 8X DVD-Writer / 24X CD-Writer, RoHS:YL | ||
n/a | 390-0345 | Slimline 8X DVD-Writer / 24X CD-Writer, RoHS:Y | ||
n/a | 390-0349 | Slimline 8X DVD-ROM / 24X CD-ROM, RoHS:Y | ||
n/a | F390-0429 | Slimline 8X DVD-Writer / 24X CD-Writer, RoHS:Y | ||
|
|
|||
|
|
|||
n/a | 390-0336 | Slimline 8X DVD-ROM / 24X CD-ROM, RoHS:Y |
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SGXPCI2SCSILM320-Z | 375-3365 | PCI Dual Ultra320 SCSI Adapter, RoHS:YL |
SunFire V490 Server Setup and Rackmounting Guide | HTML | |
SunFire V490 Server Administration Guide | HTML | |
SunFire V490 Server Product Notes | ||
SunFire V490 Parts Installation and Removal Guide | ||
SunFire V490/V890 CPU/Memory Module Configuration Guide | ||
SunFire V490/V890 Servers with 2100MHz CPU/Memory Modules Supplement | ||
Sun Remote System Control (RSC) 2.2.3 Release Notes | HTML | |
Sun Flash PROM Guide for Workstations and Workgroup Servers – Standalone Version | HTML | |
OpenBoot PROM Enhancements for Diagnostic Operation | HTML | |
2-Gbyte Memory Module Guide for Sun Fire High-End and Midrange Systems |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.