Processor | |
Number | Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs) |
Architecture | 900-MHz, 1050-MHz, or 1200-MHz UltraSPARC III Cu |
Cache memory | 64-KB data and 32-KB instruction
Secondary: 8-MB external |
Main Memory | |
Capacities | 8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board
256-MB, 512-MB, or 1-GB expansion (16GB maximum per CPU/Memory board, 32GB maximum when configured with 4 processors) Note: Install DIMMs in groups of four. 1050MHz & faster CPU/Memory boards require that all memory DIMM slots be fully populated. |
Standard Interfaces | |
Ethernet | Two 10/100/1000BASE-T twisted-pair ethernet ports (RJ-45) |
FC-AL | One Fibre Channel Arbitrated Loop (FC-AL) high-speed serial data connector (HSSDC) |
Keyboard and mouse | USB |
PCI | Six PCI slots compliant with PCI specification Revision 2.1:
|
Remote System Controller | One RSC card plugs into a dedicated slot on the system I/O board which includes integrated modem, serial and Ethernet interfaces.
|
Serial | One RJ45 serial port |
USB | Two standard Universal Serial Bus (USB) Type A connectors |
Internal Mass Storage | |
Disks | Two front-accessible, hot-swappable, FC-AL disks, 36-GB, 73-GB or 146-GB, 3.5-in. x 1.0-in. 10,000 RPM |
DVD-ROM | 8x DVD-ROM (IDE) drive |
Power Supplies | |
Type | One required, two for N+1 redundancy (hot swap), each with independent power cord |
Output | 560 W per power supply |
Environment | |
AC input | 100 – 240 VAC, 50 – 60 Hz, 8.6 A(max) |
Input power | 1100 W (max) |
Heat output | 3751 BTU/hr (max) |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20%to 80% relative temperature humidity, noncondensing Nonoperating: 5% to 95% relative temperature humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.) Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
Operating: 74.5 dBA Idling: 74.5 dBA |
Vibration |
Operating: .0002 G/Hz, 5 – 500 Hz (random) (deskside) .0001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted) Nonperating: .002 G/Hz, 5 – 500 Hz (random) (deskside) .001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted) |
Shock |
Operating: 4G peak, 11 milliseconds half-sine pulse (deskside) 3G peak, 11 milliseconds half-sine pulse (rackmounted) Nonoperating: 15G peak, 11 milliseconds half-sine pulse (deskside) 10G peak, 11 milliseconds half-sine pulse (rackmounted) |
Number of cords | 2 (max) |
1 Refers to total input current required for both AC inlets when operating with dual power supplies or current required for a single AC inlet when operating with a single power supply. | |
Regulations Meets or exceeds the following requirements: |
|
Safety | UL 60950, CSA C22.2 EN 60950 (from U.L.), TUV 60950, UL CB scheme IEC 950 (CE mark), GOST |
RFI/EMI | Class A:Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B |
Immunity | EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, IEC 61000-3-2, and IEC 61000-3-3 |
X-ray | U..DHHS 21CFR Subchapter J,PTB German X-ray Decree |
Dimensions and Weights | |
Height | 22.2 cm (8.75 in.), 5 Rack Units |
Width | 44.6 cm (17.5 in.) |
Depth | 61.0 cm (24.0 in.) |
Weight | 35.8 kg (79 lb.) (minimum) 44 kg (97 lb.) (fully configured) |
Power cord | 2.5 m (8.2 ft) |
Backplane/Centerplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-5819 | Centerplane | ||
n/a | 501-5822 | 2-Slot FC-AL Disk Backplane | ||
n/a | 501-6733 | Centerplane (Sun Services) | ||
n/a | 501-6780 | Centerplane (FAB 270-5819-06) | ||
n/a | 501-6790 | Centerplane (FAB 270-5819-07) | ||
n/a | 501-7322 | FC-AL Backplane Assembly, RoHS:YL | ||
|
|
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 150-2850 | 3V Lithium Battery BR1632 / CR1632, RoHS:Y |
Boot PROM | ||
---|---|---|
Socket | Manufacturing Part # |
Patch |
U3505 | 525-1887 | 118322 |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X311L | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-1097 | IEC 320 C13 to NEMA 5-15P – 15A/125V 2.5M Black, RoHS:Y | |||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
X913A | 130-4332 | FastWide to Narrow SCSI Adapter, RoHS:YL | ||
X9715A | 537-1020 | Fibre Optical Cable SC/SC, 5M | ||
X973A | 537-1004 | Fibre Channel Optical Cable 50/125 Multimode, 2M | ||
X978A | 537-1006 | Fibre Channel Optical Cable 50/125 Multimode, 15M | ||
X3830A | 530-2454 | External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M | ||
X3831A | 530-2455 | External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M | ||
X3872A | 130-3034 | HD15F to DB13W3M Adapter | ||
X470A | 530-2357 | Video Connector Adapter, 13W3F to HD15M | ||
X9713A | 530-3018 | Loop-B FC-AL Cable | ||
n/a | 530-1819 | Localized Power Cord Kit – Danish | ||
n/a | 530-3013 | FC-AL Backplane Power Cable | ||
n/a | 530-3069 | FC-AL Backplane Data Cable | ||
n/a | 540-5064 | Front Fan Tray Cable w/ Bracket 340-7241 |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1074A | 370-3868 | SCI Adapter (SCI/P) | ||
X1133A | 375-0130 | Crypto Accelerator I | ||
X1155A | 370-2728 | High Speed Serial Interface PCI (HSI/P) 2.0 | ||
X1157A | 501-3028 | SunATM-155/MFiber PCI 4.0 | ||
X1158A | 501-3027 | SunATM-155/UTP PCI 4.0 | ||
X1159A | 501-3029 | SunATM-622/MFiber PCI 4.0 | ||
X2156A | 375-0100 | Serial Asynchronous Interface PCI (SAI/P) 3.0 | ||
X3895A | 370-3922 | Cluster 4 port SCI switch, Dolphin Model D515 | ||
X3901A | 530-2869 | Cluster SCI Cable, 2M | ||
X3903A | 530-2871 | Cluster SCI Cable, 7.5M | ||
X3904A | 530-2872 | Cluster SCI Cable, 10M | ||
X4011A | 501-6039 | Crypto Accelerator 4000 UTP (copper) | ||
X4012A | 501-6040 | Crypto Accelerator 4000 MMF (fiber) | ||
X4111A | 501-6039 | Crypto Accelerator 4000 UTP (copper) | ||
X4112A | 501-6040 | Crypto Accelerator 4000 MMF (fiber) | ||
X4810A | 540-4721 | Sun OC48 Packet Over Sonet | ||
X6762A | 375-3089 | Crypto Accelerator 1000 | ||
n/a | 501-5856 | Remote System Control (RSC2) Board | ||
n/a | 501-6767 | Advanced Lights Out Manager Plus Card |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
XRA-FC1CB-146G10K | 540-6605 | 146GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
X6724A | 540-4525 | 36.4GB – 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
X6805A | 540-6604 | 73.4GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-5408 | 73.4GB – 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-5459 | 146GB – 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4445A | 501-6738 | Quad GigaSwift PCI-X Ethernet (QGE-X), RoHS:Y | ||
X5544A-4 | 10Gb PCI-X Ethernet Adapter, no transceiver, RoHS:Y | |||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
X5558A | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
X5560A-Z | 375-3495 | 10Gb/sec XFP Optical Transceiver Long Range (LR), RoHS:Y | ||
4455A | 10Gb PCI-X Ethernet Adapter w/ Transceiver (low-profile brackets) | |||
375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | |||
501-7163 | 10Gb/sec PCI-X Ethernet Adapter | |||
|
|
|||
4455A-4 | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
501-7414 | 10Gb/sec PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
4466A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL | ||
501-7414 | 10Gb/sec PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
5544A | 10Gb PCI-X Ethernet Adapter w/ Transceiver (standard brackets) | |||
375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | |||
501-7036 | 10Gb/sec PCI-X Ethernet Adapter | |||
|
|
|||
5544A-4 | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
6644A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL | ||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
X1033A | 501-5019 | Sun FastEthernet PCI Adapter (FE/P) 2.0 | ||
X1034A | 501-5406 | Quad FastEthernet PCI (QFE/P) | ||
X1141A | 501-4373 | Gigabit Ethernet PCI (GBE/P) 2.0 | ||
X1150A | 501-5902 | Sun GigaSwift Ethernet UTP (Copper) | ||
X1151A | 501-5524 | Sun GigaSwift Ethernet MMF (Fiber) | ||
X3150A | 501-5902 | Sun GigaSwift Ethernet UTP (Copper) | ||
X3151A | 501-5524 | Sun GigaSwift Ethernet MMF (Fiber) | ||
X4150A | 501-6719 | GigaSwift Ethernet UTP (GCS) | ||
X4151A | 501-6762 | GigaSwift Ethernet MMF (GFS) | ||
X4444A | 501-6522 | Quad GigaSwift Ethernet UTP (QGE) | ||
X5544A | 10Gb PCI-X Ethernet Adapter, no transceiver | |||
370-7792 | Bracket Low-Profile 10Gb PCI-X Ethernet, RoHS:Y | |||
501-7036 | 10Gb/sec PCI-X Ethernet Adapter | |||
|
|
|||
X5559A | 375-3361 | XFP Optical PCI-X Transceiver Single Mode Fibre, RoHS:YL |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-EM2 | 375-3304 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-JF2 | 375-3156 | JNI 2Gb PCI Single FC Host Adapter | ||
SG-XPCI1FC-QF2 | 375-3102 | 2Gb PCI Single FC Host Adapter | ||
SG-XPCI1FC-QL2 | 375-3383 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM2 | 375-3305 | 2Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-JF2 | 375-3157 | JNI 2Gb PCI Dual FC Host Adapter | ||
SG-XPCI2FC-QF2 | 375-3108 | 2Gb PCI Dual FC Host Adapter | ||
|
|
|||
SG-XPCI2FC-QF2-Z | 375-3363 | 2Gb PCI Dual FC Host Adapter, RoHS:Y | ||
|
|
|||
X6727A | 375-3030 | PCI Dual FC Host Adapter+, RoHS:YL | ||
X6767A | 375-3102 | 2Gb PCI Single FC Host Adapter | ||
X6768A | 375-3108 | 2Gb PCI Dual FC Host Adapter | ||
|
|
|||
X6799A | 375-3019 | PCI Single FC Host Adapter |
Graphics | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1089A | 370-4072 | SunVideo Plus | ||
X3668A | 370-3753 | PGX32 8/24-Bit Color Frame Buffer | ||
X3685A | 375-3069 | XVR-500 Graphics Accelerator | ||
X3768A | 370-4362 | PGX64 8/24-Bit Color Frame Buffer | ||
X3769A | 375-3126 | XVR-100 Graphics Accelerator (32MB) | ||
X3770A | 375-3181 | XVR-100 Graphics Accelerator (64MB) | ||
X3780A | 375-3153 | XVR-600 Graphics Accelerator | ||
X7296A | 375-3290 | XVR-100 Graphics Accelerator (64MB), RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-5820 | PCI I/O Riser Board | ||
|
|
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7056A | 4 GB (4 × 1GB SDRAM DIMMs) | |||
501-7386 | 1GB SDRAM DIMM, RoHS:YL | |||
X7051A | 2 GB (4 × 512MB SDRAM DIMMs) | |||
501-7385 | 512MB SDRAM DIMM, RoHS:YL | |||
X7051A-Z | 2 GB (4 × 512MB SDRAM DIMMs), RoHS:YL | |||
501-7385 | 512MB SDRAM DIMM, RoHS:YL | |||
X7053A | 1 GB (4 × 256MB SDRAM DIMMs) | |||
501-5401 | 256MB SDRAM DIMM | |||
X7056A-Z | 4 GB (4 × 1GB SDRAM DIMMs), RoHS:YL | |||
501-7386 | 1GB SDRAM DIMM, RoHS:YL | |||
n/a | 501-5030 | 512MB SDRAM DIMM | ||
n/a | 540-5086 | 1GB SDRAM DIMM | ||
F511-1030 | Package of 25 × 512MB SDRAM DIMMs | |||
|
|
|||
F511-1031 | Package of 25 × 1GB SDRAM DIMMs | |||
|
|
Miscellaneous | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X2132A | 375-3051 | SunPCi IIpro 733MHz coprocessor card | ||
X2134A | 375-3116 | SunPCi III 1.4GHz Co-Processor Card, 256MB memory | ||
X7042A | 370-4294 | SunPCi II 128MB memory expansion | ||
X7044A | 370-4295 | SunPCi II 256MB memory expansion | ||
X7045A | 370-4430 | SunPCi IIpro 512MB memory expansion | ||
X7066A | 370-5463 | SunPCi III 256MB SODIMM memory expansion | ||
X7067A | 370-5967 | SunPCi III 512MB SODIMM memory expansion | ||
X9631A | 595-6188 | 2-Post Rackmount Kit |
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 300-1480 | Tyco 1184 Watt Power Supply | ||
n/a | 375-3006 | DC Power Distribution Board |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SR9-XKL038A-IP | 595-6712 | Sun Rack 900, Empty X-Option Rack without Power, RoHS:Y | ||
SF-XCAB | 540-4613 | Sun Fire Cabinet | ||
SG-XARY030A | 595-4706 | 72 inch Sun StorEdge Expansion Cabinet | ||
n/a | 370-4427 | 4-Post Rack Kit (370-4427-02 = 27″) – discontinued June 2002 (370-4427-03 = 25″) – obsolete (370-4427-04 = 25″) – add slide kit, RoHS:YL |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-4412 | Slimline 8X DVD-ROM / 24X CD-ROM |
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SGXPCI2SCSILM320-Z | 375-3365 | PCI Dual Ultra320 SCSI Adapter, RoHS:YL | ||
SG-XPCI2SCSI-LM320 | 375-3191 | PCI/PCI-X Dual Ultra320 SCSI Adapter | ||
X1032A | 501-5656 | Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) | ||
X2222A | 501-5727 | Dual FastEthernet / Dual SCSI PCI Adapter | ||
X4422A | 501-6635 | Dual GigabitEthernet / Dual SCSI PCI Adapter | ||
X6540A | 375-0005 | Dual Single-Ended Ultra/Wide SCSI (PCI) | ||
X6541A | 375-0006 | Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) | ||
X6758A | 375-3057 | PCI Dual Ultra3 SCSI Host Adapter (LVD) |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.