This power 2U monster is powered by either 1 x 1.34 GHz or 2 x 1.5 GHz UltraSPARC® IIIi processors, the Sun Fire V240TM server is an entry-level, data center-class server. It provides high availabil- ity and expandability in a compact, 2U package. Four autonegotiating Gigabit Ethernet ports provide multiple connectivity for high-speed, high-bandwidth networking, while hot-swap- pable, front-accessible disk drives and redundant, hot-swappable power supplies (with inde- pendent cords) further enhance the Sun Fire V240 server’s uptime. With expandability fea- tures such as three PCI slots, up to four disk drives, and 16 GB of memory, the rack-optmized Sun Fire V240 server easily scales to meet the needs of Tier 1 and Tier 2 applications. With a low-cost, integrated SSL option on the motherboard, the Sun Fire V240 server provides fast, secure Web transactions without sacrificing CPU cycles or a PCI slot. The standard System Configuration Card and serviceability features help enable quick upgrades and repairs, while the unit’s Sun Advanced Lights Out Manager (ALOM) provides remote management to a large number of servers from almost anywhere on the network.
Sun V240 Processor | |
Number | One or two |
Architecture | 1GHz, 1.28GHz, 1.33GHz, or 1.5GHz UltraSPARC® IIIi, 64 bit, 4-way Superscalar SPARC® V9 |
Cache memory | 64 KB data, 32 KB instruction and 1 MB integrated L2 |
Main Memory | |
Capacities |
4 DIMM slots per processor, registered DDR-1 SDRAM (PC2100/PC2700) 128 bit + ECC databus System configurations from 512 MB to 16 GB |
Standard Interfaces | |
Ethernet |
Four 10/100/1000 BaseT Ethernet One 10 BaseT Ethernet (Network Management) |
PCI | Three internal PCI 2.2 compliant expansion slots: One 64 bit 33/66 MHz 3.3V full-length Two 64 bit 33 MHz 5V full-lengthNote:Nominal power = maximum 25W per slot, maximum 45W across 3 slots |
SCSI | One Ultra160 SCSI multimode (SE/LVD) |
Serial |
One TIA/EIA-232-F asynchronous (DB9) Port One TIA/EIA-232-F (RJ45) Port (Serial Management) |
System Configuration Reader and Card | Front accessible for transfer of system configuration information, including host ID |
USB | Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of 12 and 1.5 Mbits/sec each |
Internal Mass Storage | |
Disks | Up to four hot-swap Ultra160 SCSI 36GB, 73GB, or 146GB Disks |
DVD-ROM | One Slim-line ATAPI DVD-ROM (Optional) |
Environment | |
AC input | 90 – 264 VAC (47 – 63 Hz) |
Input power | 546 W |
Nominal power (calculated at 240V/50Hz) |
Minimum configuration: 215 Watts (1 × 1.34GHz processor, 2 × 256MB DIMMs, 1 × 73GB HDD) Maximum configuration: 442 Watts (2 × 1.5GHz processors, 8 × 1GB DIMMs, 2 × 73GB HDDs, Crypto 500, 1 × DVD-ROM, 3 × PCI cards [max power spec 45W for three cards]) Typical Minimum configuration: 200 Watts (1 × 1.34GHz processor, 2 × 256MB DIMMs, 1 × 73GB HDD) Typical Maximum configuration: 329 Watts (2 × 1.5GHz processors, 8 × 1GB DIMMs, 2 × 73GB HDDs, Crypto 500, 1 × DVD-ROM, 3 × PCI cards [max power spec 45W for three cards]) |
Heat dissipation |
Minimum configuration: 798 BTU/hr Maximum configuration: 1639 BTU/hr |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F) Nonoperating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing, 27° C max wet bulb Nonoperating: Up to 93% relative humidity, noncondensing, 38° C max wet bulb |
Altitude |
Operating: Up to 3000 m, maximum ambient temperature is derated by 1° C per 500 m above 500 m Nonoperating: Up to 12000 m |
Acoustic noise | Operating: Less than 7.3 B sound power in ambient temperature of up to 24° C |
Regulations Meets or exceeds the following requirements: |
|
Safety | IEC60950, UL/CSA60950, EN60950 |
Emissions | FCC Class A, Part 15 47 CFR, EN55022, CISPR 22 |
Immunity | EN55024 |
Certification |
Safety: cULus Mark, TUV GS Mark, CE Mark EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK |
Dimensions and Weights | |
Height | 87.66 mm (3.4 in.) (2 RU) |
Width | 425 mm (16.73 in.) |
Depth | 635 mm (25 in.) |
Weight | 19 kg (41.8 lb.) fully configured; 22.4 kg (49.31 lb.) with rack-mount rails and cable management arm |
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 371-0090 | 3V Lithium Battery BR2032 |
Boot PROM | ||
---|---|---|
Socket | Manufacturing Part # |
Patch |
U55 | 254-0078 | 116056 |
U55 | 254-0090 | 116056 |
CPU Module | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7406A | 595-7222 | 1GHz processor for V210/V240 (includes 1 of the following CPUs) | ||
|
|
|||
|
|
|||
|
|
|||
X7412A | 595-7223 | 1.28GHz UltraSPARC IIIi processor upgrade kit with heatsink | ||
|
|
|||
|
|
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X311L | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-1097 | IEC 320 C13 to NEMA 5-15P – 15A/125V 2.5M Black, RoHS:Y | |||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X320A | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-2164 | IEC 320 C13 to NEMA 6-15P – 10A/250V 2.0M Black, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
X9280A | 530-3387 | 4X SFF8470 to 12X SFF8470 InfiniBand Cable, 2 Meter | ||
X9281A | 530-3386 | 4X SFF8470 to 12X SFF8470 InfiniBand Cable, 5 Meter | ||
n/a | 370-5137 | Cable Kit | ||
n/a | 530-1351 | IEC 320 C13 to NEMA 6-15 – 10A/250V 2.0M Black, RoHS:Y | ||
n/a | 530-1819 | Localized Power Cord Kit – Danish | ||
n/a | 530-2961 | RJ45 Cat5 Ethernet Cable, RoHS:Y | ||
n/a | 530-3100 | RJ45F to DB9F Adapter, RoHS:Y | ||
n/a | 530-3566 | RME KEY SWITCH Cable, RoHS:Y |
Card/Reader | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-5127 | System Configuration Card Reader | ||
n/a | 370-5155 | System Configuration Card, RoHS:Y | ||
n/a | 371-0795 | System Configuration Card with 10 MAC Addresses, RoHS:Y | ||
n/a | 371-0838 | System Configuration Card Reader, RoHS:YL | ||
n/a | 371-3551 | System Configuration Card with 10 MAC Addresses, Polycarbonate, RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1355A-2 | 371-0982 | 2M, 80-Pin, 4-Port, DB37, RS449 Breakout Cable,RoHS:Y | ||
375-3296 | Quad Port High Speed Serial Interface PCI-X (HSI/U), RoHS:Y | |||
X2156A-2 | 375-3420 | Serial Asynchronous Interface PCI (SAI/P) 3.0, RoHS:Y | ||
X1155A | 370-2728 | High Speed Serial Interface PCI (HSI/P) 2.0 | ||
X1157A | 501-3028 | SunATM-155/MFiber PCI 4.0 | ||
X1233A | 375-3259 | Dual Port 4x InfiniBand Host Channel Adapter | ||
X2156A | 375-0100 | Serial Asynchronous Interface PCI (SAI/P) 3.0 | ||
X4011A | 501-6039 | Crypto Accelerator 4000 UTP (copper) | ||
X4012A | 501-6040 | Crypto Accelerator 4000 MMF (fiber) | ||
X4111A | 501-6039 | Crypto Accelerator 4000 UTP (copper) | ||
X4112A | 501-6040 | Crypto Accelerator 4000 MMF (fiber) | ||
X7405A | 370-5464 | Hardware Cryptographic Module (Crypto Accelerator 500) | ||
X7405A-4 | 371-0991 | Hardware Cryptographic Module (Crypto Accelerator 500), RoHS:YL |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X5267A | 540-4904 | 36.4GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
X5268A | 540-6602 | 146.8GB – 10000 RPM, Disk Assembly with 1 bracket, 1 plate and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SC1CB-73G10K | 540-6600 | 73.4GB – 10000 RPM, Disk Assembly with 1 bracket, 1 plate and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-5455 | 73.4GB – 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-6064 | 146.8GB – 10000 RPM, Disk Assembly with 1 bracket, 1 plate, and 1 of the following disks: | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X4150A-2 | 501-7415 | GigaSwift Ethernet UTP (GCS), RoHS:Y | ||
X4151A-2 | 501-7430 | GigaSwift Ethernet MMF (GFS), RoHS:Y | ||
X4445A | 501-6738 | Quad GigaSwift PCI-X Ethernet (QGE-X), RoHS:Y | ||
X1033A | 501-5019 | Sun FastEthernet PCI Adapter (FE/P) 2.0 | ||
X1034A | 501-5406 | Quad FastEthernet PCI (QFE/P) | ||
X1141A | 501-4373 | Gigabit Ethernet PCI (GBE/P) 2.0 | ||
X1150A | 501-5902 | Sun GigaSwift Ethernet UTP (Copper) | ||
X1151A | 501-5524 | Sun GigaSwift Ethernet MMF (Fiber) | ||
X3150A | 501-5902 | Sun GigaSwift Ethernet UTP (Copper) | ||
X3151A | 501-5524 | Sun GigaSwift Ethernet MMF (Fiber) | ||
X4150A | 501-6719 | GigaSwift Ethernet UTP (GCS) | ||
X4151A | 501-6762 | GigaSwift Ethernet MMF (GFS) | ||
X4444A | 501-6522 | Quad GigaSwift Ethernet UTP (QGE) |
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-5134 | 60mm Fan | ||
n/a | 370-7678 | Fan Tray Assembly/FRU | ||
|
|
|||
|
|
|||
n/a | 371-0837 | CPU Fan/Heatsink, RoHS:Y | ||
n/a | 371-0992 | Fan Tray Assembly/FRU, RoHS:Y | ||
|
|
|||
|
|
|||
n/a | F370-5126 | CPU Fan/Heatsink FRU | ||
|
|
|||
|
|
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM4-Z | 375-3399 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-EM2 | 375-3304 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-JF2 | 375-3156 | JNI 2Gb PCI Single FC Host Adapter | ||
SG-XPCI1FC-JN2 | 370-5702 | JNI 2Gb PCI Single FC HBA | ||
SG-XPCI1FC-QF2 | 375-3102 | 2Gb PCI Single FC Host Adapter | ||
SG-XPCI1FC-QL2 | 375-3383 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM2 | 375-3305 | 2Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-JF2 | 375-3157 | JNI 2Gb PCI Dual FC Host Adapter | ||
SG-XPCI2FC-QF2 | 375-3108 | 2Gb PCI Dual FC Host Adapter | ||
|
|
|||
SG-XPCI2FC-QF2-Z | 375-3363 | 2Gb PCI Dual FC Host Adapter, RoHS:Y | ||
|
|
|||
X6727A | 375-3030 | PCI Dual FC Host Adapter+, RoHS:YL | ||
X6767A | 375-3102 | 2Gb PCI Single FC Host Adapter | ||
X6768A | 375-3108 | 2Gb PCI Dual FC Host Adapter | ||
|
|
|||
X6799A | 375-3019 | PCI Single FC Host Adapter |
Graphics | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X3685A | 375-3069 | XVR-500 Graphics Accelerator | ||
X3768A | 370-4362 | PGX64 8/24-Bit Color Frame Buffer | ||
X3769A | 375-3126 | XVR-100 Graphics Accelerator (32MB) | ||
X3770A | 375-3181 | XVR-100 Graphics Accelerator (64MB) | ||
X3780A | 375-3153 | XVR-600 Graphics Accelerator | ||
X7296A | 375-3290 | XVR-100 Graphics Accelerator (64MB), RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-5465 | PCI Riser Board | ||
n/a | 370-7087 | PCI Riser Board | ||
n/a | 371-0799 | 2-Slot PCI Riser, RoHS:YL | ||
n/a | F370-5183 | Interface Boards FRU | ||
|
|
|||
|
|
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7402A | 512MB DDR Memory Option (2 × 256MB DIMMs) | |||
370-5565 | 256MB Registered DDR DIMM (SPD 0.0) | |||
X7403A | 1GB DDR Memory Option (2 × 512MB DIMMs) | |||
370-4939 | 512MB Registered DDR DIMM (SPD 0.0) | |||
X7404A | 2GB DDR Memory Option (2 × 1GB DIMMs) | |||
370-4940 | 1GB Registered DDR DIMM (SPD 0.0) | |||
X7602A | 512MB DDR Memory Option, SPD 1.0 (2 × 256MB DIMMs) | |||
370-6201 | 256MB Registered DDR DIMM (SPD 1.0) | |||
X7603A | 1GB DDR Memory Option, SPD 1.0 (2 × 512MB DIMMs) | |||
370-6202 | 512MB Registered DDR DIMM (SPD 1.0) | |||
X7604A | 2GB DDR Memory Option, SPD 1.0 (2 × 1GB DIMMs) | |||
370-6203 | 1GB Registered DDR DIMM (SPD 1.0) | |||
X7702A | 512MB DDR Memory Option, SPD 0.0 or 1.0 (2 × 256MB DIMMs) | |||
370-7680 | 256MB Registered DDR DIMM (SPD 0.0 or 1.0) PC2100 & faster | |||
X7702A-4 | 512MB DDR1 Memory Option, (2 × 256MB DIMMs), RoHS:YL | |||
371-1115 | 256MB Registered ECC DDR1 DIMM (SPD 0.0 or 1.0) PC2100 & faster, RoHS:YL | |||
X7703A | 1GB DDR Memory Option, SPD 0.0 or 1.0 (2 × 512MB DIMMs) | |||
370-7670 | 512MB Registered DDR DIMM (SPD 0.0 or 1.0) PC2100 & faster | |||
X7703A-4 | 1GB DDR Memory Option, (2 × 512MB DIMMs), RoHS:YL | |||
370-7972 | 512MB PC2700 DIMM, RoHS:Y | |||
371-1116 | 512MB Registered ECC DDR1 DIMM (SPD 0.0 or 1.0) PC2100 & faster, RoHS:YL | |||
X7704A | 2GB DDR Memory Option, SPD 0.0 or 1.0 (2 × 1GB DIMMs) | |||
370-7671 | 1GB Registered DDR DIMM (SPD 0.0 or 1.0) PC2100 & faster | |||
X7704A-4 | 2GB DDR1 Memory Option, (2 × 1GB DIMMs), RoHS:YL | |||
370-7973 | 1GB PC2700 DIMM, RoHS:Y | |||
371-1117 | 1GB Registered ECC DDR1 DIMM (SPD 0.0 or 1.0) PC2100 & faster, RoHS:YL | |||
X7711A-4 | 4GB DDR Memory Option, SPD 0.0 or 1.0 (2 × 2GB DIMMs), RoHS:YL | |||
370-7672 | 2GB Registered DDR DIMM (SPD 0.0 or 1.0) PC2100 & faster, RoHS:YL | |||
370-7974 | 2GB PC2700 DIMM, RoHS:Y | |||
n/a | 540-6228 | 512MB DDR FRU, SPD 1.0 (2 × 256MB DIMMs) | ||
|
|
|||
n/a | 540-6229 | 1GB DDR FRU, SPD 1.0 (2 × 512MB DIMMs) | ||
|
|
|||
n/a | 540-6230 | 2GB DDR FRU, SPD 1.0 (2 × 1GB DIMMs) | ||
|
|
|||
n/a | 540-6399 | 512MB DDR FRU, SPD 0.0/1.0 (2 × 256MB DIMMs) | ||
|
|
|||
n/a | 540-6400 | 1GB DDR FRU, SPD 0.0/1.0 (2 × 512MB DIMMs) | ||
|
|
|||
n/a | 540-6401 | 2GB DDR FRU, SPD 0.0/1.0 (2 × 1GB DIMMs) | ||
|
|
|||
n/a | 540-6402 | 4GB Memory FRU (2 × 2GB DIMMs), RoHS:YL | ||
|
|
|||
|
|
|||
n/a | 540-6775 | 512MB Memory FRU (2 × 256MB DIMMS), RoHS:YL | ||
|
|
|||
n/a | 540-6776 | 1GB Memory FRU (2 × 512MB DIMMS), RoHS:YL | ||
|
|
|||
|
|
|||
n/a | 540-6777 | 2GB Memory FRU (2 × 1GB DIMMS), RoHS:YL | ||
|
|
|||
|
|
Miscellaneous | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X2132A | 375-3051 | SunPCi IIpro 733MHz coprocessor card | ||
X7042A | 370-4294 | SunPCi II 128MB memory expansion | ||
X7044A | 370-4295 | SunPCi II 256MB memory expansion | ||
X7045A | 370-4430 | SunPCi IIpro 512MB memory expansion | ||
n/a | 371-2356 | PCI Card Rail and Clip |
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7407A | 300-1568 | 400W AC Input Power Supply Type A178 |
||
X7428A | 300-1674 | 400W AC Input Power Supply Type A192 |
||
X7428A-4 | 300-1846 | 400W AC Power Supply Type A192, RoHS:YL | ||
n/a | 370-5138 | DC Power Distribution Board |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 371-0066 | Rack Mount/Cable Management Kit, RoHS:Y | ||
|
|
|||
|
|
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X7410A | 370-5128 | Internal Slimline DVD-ROM (ATAPI) | ||
X7410A-4 | 371-1108 | Internal 8X Slimline DVD-ROM/CD-ROM, RoHS:YL | ||
|
|
|||
|
|
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SGXPCI2SCSILM320-Z | 375-3365 | PCI Dual Ultra320 SCSI Adapter, RoHS:YL | ||
X4422A-2 | 501-7490 | Dual GigabitEthernet / Dual SCSI PCI Adapter, RoHS:Y | ||
SG-XPCI2SCSI-LM320 | 375-3191 | PCI/PCI-X Dual Ultra320 SCSI Adapter | ||
X1032A | 501-5656 | Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) | ||
X2222A | 501-5727 | Dual FastEthernet / Dual SCSI PCI Adapter | ||
X4422A | 501-6635 | Dual GigabitEthernet / Dual SCSI PCI Adapter | ||
X6540A | 375-0005 | Dual Single-Ended Ultra/Wide SCSI (PCI) | ||
X6541A | 375-0006 | Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) | ||
X6758A | 375-3057 | PCI Dual Ultra3 SCSI Host Adapter (LVD) |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.