Processor | |
Number | 1 |
Architecture | 1.0/1.2/1.4-GHz UltraSPARC T1 Chip Multithreaded (CMT) 1.4 GHz is 8 core 1.2 GHz is 8 core 1.0 GHz are 4 or 8-core CoolThreads Server ECO-Responsible Server |
Cache memory | 3 MB unified level 2 cache with ECC |
Main Memory | |
Capacities |
DIMM slots per memory controller: 4 DIMM type: DDR2 ECC registered DIMMs DIMM size: 512-MB, 1-GB, 2-GB, or 4-GB Maximum capacity: 64GB (when configured with 4-GB DIMMs) Note: DIMMS must be installed in sets of 8. Two basic memory configurations are supported: 8-DIMM or 16-DIMM. All DIMMs must have identical capacity. An 8 DIMM configuration fully populates Rank 0 slots. |
Standard Integrated Interfaces | |
Network | Four 10/100/1000 Base-T Ethernet autonegotiating ports |
Network Management | One dedicated 10/100Base-T Ethernet port |
Remote Management | SC Serial Management port and Net Management port |
USB |
Front:Two USB 1.1 ports Rear:Two USB 1.1 ports |
PCI Interfaces | Three PCI-Express low-profile, 2.5GHz lanes card slots with up to X8 data lanes. Two PCI-X low-profile, 64-bit, 133 MHz card slots. Note: Earlier models of the Sun Fire T2000 (non RoHS) used one PCI-X slot (slot 0) for the SAS disk controller. |
Internal Storage | |
Disks | Up to four 73GB or 146GB HDD Disks (Hot Pluggable, SFF, SAS, 10K RPM). |
Removable Media | 1 slimline DVD-R/CD-RW drive |
Power Supplies | |
Two hot-swappable, redundant, high efficiency 450W power supplies. Note: Earlier models of the Sun Fire T2000 (non RoHS) used 550W power supplies. The Sun SPARC Enterprise T2000, RoHS:YL server has two hot-swappable, redundant, high efficiency 450W power supplies. These are the electrical limits and ranges for the Sun SPARC Enterprise T2000 server utilizing 450 W power supplies: |
|
Operating input voltage range | 100 to 240 VAC, 50-60 Hz |
Maximum operating input current | 4.5 A at 100 to 120 VAC 2.25 A at 200 to 240 VAC |
Maximum operating input power | 400 W |
Maximum heat dissipation | 1,535 BTU/hr |
Nominal Power | 275 W |
A power calculator exists for the Sun SPARC Enterprise T2000 server, enabling customers to calculate the power of the components in their systems, providing them with an estimated overall total for different configurations. See: http://www.sun.com/servers/coolthreads/t2000/calc/index.jsp | |
Space, Watts and Performance (SWaP) | |
Space (RU) | 2 |
Watts | 300 |
Performance (application tier benchmark) | 5300 |
Performance/watt | 17.667 |
SWaP | 8.8 |
Environment | |
Temperature |
Operating (Sea Level to 3000 ft(900m)): 5° C to 35° C (41° F to 95° F) Non-operating: -40° C to 60° C (-40° F to 140° F) Operating (Above 3000 ft(900m)):Decrease maximum temperature as altitude increases, 1.6°F/1000 ft (1°C/300m) Non-operating: -40° C to 60° C (-40° F to 140° F) |
Humidity |
Operating: 20% to 80% relative humidity noncondensing, 27° C (80.6° F) web bulb, IEC 60068-2-3&56 Non-operating: 98% relative humidity 38° C (100.4 ° F) noncondensing,IEC 60068-2-3&56 |
Altitude |
Operating: up to 3000 m (10,000 ft.), IEC 60068-2-13 Non-operating: up to 12,000 m (40,000 ft.), IEC 60068-2-13 |
Acoustic noise – LPAm (bystander positions) |
Operating: 62 dB Idling: 62 dB |
Acoustic noise – LwAd (1 B = 10 dB) |
Operating: 7.7 B Idling: 7.7 B |
Vibration |
Operating: 0.2 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13 Non-operating: 1.0 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13 |
Shock |
Operating: 5.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27 Non-operating: 30.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27 |
Cooling | 3 hot-swappable and redundant system fans. 1 hot-swappable blower unit. |
Regulations Meets or exceeds the following requirements: |
|
RoHS Compliance Level | RoHS:YL |
Safety | UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC 825-1,2, CFR21 part 1040, CNS 14336, GB4943 |
Ergonomics | EK1-1TB-2000 |
RFI/EMI | EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NC 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3 |
Immunity | EN55024, IEC 61000-2, IEC 61000-3, IEC 61000-4, IEC 61000-5, IEC 61000-6, IEC 61000-8, IEC 61000-11 |
Telecommunications | EN300-386 |
Regulatory Markings (pending) | CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKO/GS, UL/S-mark, CCC |
Dimensions and Weight | |
Height (2 rack units) | 89 mm (3.5 in.) |
Width | 440 mm (17.3 in.) |
Depth | 617 mm (24.3 in.) |
Weight, approximate (without PCI cards and rack mounts) | 17 kg (37 lb.) |
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 150-1204 | 3V Lithium battery, RoHS:Y |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X311L | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-1097 | IEC 320 C13 to NEMA 5-15P – 15A/125V 2.5M Black, RoHS:Y | |||
X312E | Localized Power Code Kit – China, RoHS:Y | |||
180-1982 | IEC 320 C13 to GB 2099/GB 1002 – 10A/250V 2.5M, RoHS:Y | |||
X312F | Localized Power Cord Kit – Argentina, RoHS:Y | |||
180-1999 | IEC 320 C13 to IRAM 2073 – 10A/250V 2.5M Black, RoHS:Y | |||
X312G | Localized Power Cord Kit – Korea, RoHS:Y | |||
180-1662 | IEC 320 C13 to KSC 8305 – 15A/250V 2.5M Black, RoHS:Y | |||
X312L | Localized Power Cord Kit – Continental Europe, RoHS:Y | |||
180-1993 | IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y | |||
X314L | Localized Power Cord Kit – Swiss, RoHS:Y | |||
180-1994 | IEC 320 C13 to SEV 1011 – 10A/250V 2.5M Black, RoHS:Y | |||
X317L | Localized Power Cord Kit – U.K., RoHS:Y | |||
180-1997 | IEC 320 C13 to BS 1363 – 10A/250V 2.5M Black, RoHS:Y | |||
X320A | Localized Power Cord Kit – North America/Asia, RoHS:Y | |||
180-2164 | IEC 320 C13 to NEMA 6-15P – 10A/250V 2.0M Black, RoHS:Y | |||
X332T | International Power Cord Kit, RoHS:Y | |||
180-2071 | Blue 16A IEC 309 to IEC 320 C13 International 4.0M, RoHS:Y | |||
X333A-25-10-IL | Localized Power Cord Kit Israel, RoHS:Y | |||
180-2130 | IEC 320 C13 to SI-32, 10A/250V, 2.5M, Black, RoHS:Y | |||
X333A-25-15-JP | Localized Power Cord Kit Japan, RoHS:Y | |||
180-2243 | IEC 320 C13 to PSE 5-15P, 15A/125V, 2.5M, Black, RoHS:Y | |||
X333F-25-15-JP | Localized Power Cord Kit Japan, RoHS:Y | |||
180-2244 | IEC 320 C13 to PSE 6-15P, 15A/250V, 2.5M, Black, RoHS:Y | |||
X340L | Power Kit for North America, L6-20 20A Twist Lock Plug, RoHS:Y | |||
180-2070 | NEMA L6-20P to IEC 320 C13 – 4.0M, RoHS:Y | |||
X383L | Localized Power Cord Kit – Danish, RoHS:Y | |||
180-1995 | IEC 320 C13 to Asfnit 107 – 10A/250V 2.5M Black, RoHS:Y | |||
X384L | Localized Power Cord Kit – Italian, RoHS:Y | |||
180-1996 | IEC 320 C13 to CEI 23-16/VII – 10A/250V 2.5M Black, RoHS:Y | |||
X386L | Localized Power Cord Kit – Australian, RoHS:Y | |||
180-1998 | IEC 320 C13 to AS 3112 – 10A/250V 2.5M Black, RoHS:Y | |||
X321L | North America/Asia Power Cords 4-Pack, RoHS:Y | |||
180-2023 | IEC 320 C13 to NEMA 6-15P – 10A/250V 4.0M Black, RoHS:Y | |||
n/a | 530-3361 | CPU/Memory to I/O Board Cable, RoHS:Y | ||
n/a | 530-3365 | DVD Cable, RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X6000A | 375-3424 | PCI Express Sun Crypto Accelerator 6000, RoHS:Y | ||
X1235A | 375-3260 | PCI-X Dual Port 4x InfiniBand Host Channel Adapter – Low Profile | ||
X1236A-Z | 375-3382 | Dual Port 10Gb/sec 4x PCI Express Infiniband Host Channel Adapter – Low Profile, RoHS:Y | ||
X1333A-4 | 375-3418 | Infiniband PCI-X Card, RoHS:YL |
Disk Backplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7755 | 4-Slot Disk Backplane, RoHS:YL |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SEPX3A11Z | 540-7307 | 73GB 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
SEPX3C11Z | 540-7777 | 146GB 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SS2CD-146G10KZ | 540-7151 | 146GB – 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks and brackets, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
XRA-SS2CD-73G10KZ | 540-6611 | 73GB 10000 RPM SAS, Disk Assembly with 1 of the following disks and brackets, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1027A-Z | 501-7283 | PCI Express Dual 10-Gigabit Ethernet Fiber, RoHS:Y | ||
X4150A-2 | 501-7415 | GigaSwift Ethernet UTP (GCS), RoHS:Y | ||
X4151A-2 | 501-7430 | GigaSwift Ethernet MMF (GFS), RoHS:Y | ||
X4447A-Z | 511-1422 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
560-2884 | Ship Kit for Gigabit Ethernet options | |||
|
|
|||
X5544A-4 | 10Gb PCI-X Ethernet Adapter, no transceiver, RoHS:Y | |||
501-7413 | 10Gb PCI-X Ethernet Adapter, RoHS:Y | |||
|
|
|||
|
|
|||
X7280A-2 | 371-0905 | PCI Express Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7281A-2 | 371-0904 | PCI Express Dual Gigabit Ethernet MMF, RoHS:Y | ||
X4150A | 501-6719 | GigaSwift Ethernet UTP (GCS) | ||
X4151A | 501-6762 | GigaSwift Ethernet MMF (GFS) | ||
X5544A | 10Gb PCI-X Ethernet Adapter, no transceiver | |||
370-7792 | Bracket Low-Profile 10Gb PCI-X Ethernet, RoHS:Y | |||
501-7036 | 10Gb/sec PCI-X Ethernet Adapter | |||
|
|
|||
n/a | 501-7606 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
|
|
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-0275 | CPU fan, RoHS:YL | ||
n/a | 541-0645 | Rear Fan Tray, RoHS:Y |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM4-Z | 375-3399 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-EM4 | 375-3396 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-EM8-Z | 371-4295 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF4 | 375-3355 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF8-Z | 371-4324 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM4 | 375-3397 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM8-Z | 371-4306 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF4 | 375-3356 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF8-Z | 371-4325 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-EM2 | 375-3304 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QL2 | 375-3383 | 2Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM2 | 375-3305 | 2Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF2-Z | 375-3363 | 2Gb PCI Dual FC Host Adapter, RoHS:Y | ||
|
|
Graphics | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X3000A | 375-3545 | XVR-300 x8 Graphics Accelerator, RoHS:Y | ||
530-3474 | DVI-A(M) to HD15F Adapter, 49mm, RoHS:Y | |||
530-3998 | DMS-59 to Dual DVI-I Cable, 215mm, RoHS:Y | |||
X3777 | 375-3433 | XVR-200 Graphics Accelerator, RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-6978 | Front I/O Board w/Cover Interlock Switch, RoHS:YL |
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SEKX2A1Z | 1GB (2 x 512MB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6207 | 512MB DDR2 DIMM, 533 MHz, RoHS:Y | |||
SEKX2B1Z | 2GB (2 x 1Gb DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6208 | 1GB DDR2 DIMM, 533 MHz, RoHS:Y | |||
SEKX2C1Z | 4GB (2 x 2GB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6209 | 2GB DDR2 DIMM, 533 MHz, RoHS:Y | |||
SEKX2D1Z | 8GB (2 x 4GB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6210 | 4GB DDR2 DIMM, RoHS:Y | |||
X7800A | 1GB (2 × 512MB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6207 | 512MB DDR2 DIMM, 533 MHz, RoHS:Y | |||
X7801A | 2GB (2 × 1GB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6208 | 1GB DDR2 DIMM, 533 MHz, RoHS:Y | |||
X7802A | 4GB (2 × 2GB DDR2) Memory Expansion Kit, RoHS:Y | |||
370-6209 | 2GB DDR2 DIMM, 533 MHz, RoHS:Y | |||
X7803A | 8GB (2 × 4GB DDR2) Memory Expansion Kit | |||
370-6210 | 4GB DDR2 DIMM, RoHS:Y |
Miscellaneous | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-6916 | LED/Switch Board (A65/A87), RoHS:Y |
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7021 | Power Distribution Board, RoHS:YL | ||
n/a | F300-1735 | 450 Watt Power Supply, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 370-7668 | Cable Management Arm, RoHS:Y | ||
n/a | 370-7669 | Slide Rail Kit, RoHS:Y |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 390-0251 | Slimline 8X DVD-ROM / 24X CD-Writer,RoHS:Y | ||
n/a | 541-1474 | DVD Cable Assembly, RoHS:YL | ||
|
|
|||
|
|
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI8SAS-E-Z | 375-3488 | 3Gb PCI-X SAS 8-Port Host Adapter, RoHS:Y | ||
SG-XPCIE2SCSIU320Z | 375-3357 | Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y | ||
SGXPCI1SCSILM320-Z | 375-3366 | PCI Single Ultra320 SCSI Adapter | ||
SGXPCIESAS-R-EXT-Z | 371-3253 | Lithium Ion Battery Module | ||
375-3537 | 8-Port SAS RAID External HBA, RoHS:Y | |||
SG-XPCI1SCSI-LM320 | 375-3255 | PCI/PCI-X Single Ultra320 SCSI Adapter |
System Board | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-2142 | 0MB 8-Core 1.0GHz System Board, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2192 | 0MB 8-Core 1.2GHz System Board, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2226 | 0MB 4-Core 1.0GHz System Board, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 541-2449 | 0MB 8-Core 1.4GHz System Board, RoHS:YL | ||
|
|
|||
|
|
|||
|
|
|||
|
|
System Service Processor | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 501-7849 | Service Processor, RoHS:YL | ||
|
|
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.