Greentec Systems is proud to offer Oracle’s refurbished SPARC T7 servers that are the world’s most advanced systems for enterprise workloads, with unique capabilities for information security, database and Java acceleration. Breakthrough Software in Silicon technology in Oracle’s new SPARC processor provides full speed encryption, plus detection and prevention of attacks to critical data in memory. It also enables real time analytics to be performed on OLTP databases by accelerating Oracle Database In-Memory queries in Oracle Database 12c. The combination of the world’s highest performance with breakthrough Software in Silicon features is the foundation to building the best and most secure mission critical clouds.
Oracle’s SPARC T7-2 server is a two-processor system that enables organizations to respond to IT demands with extreme security and performance, at a lower cost compared to alternatives. It is ideal for a wide range of enterprise class workloads, including database, applications, Java, and middleware, especially in a cloud environment. This system is based on the SPARC M7 processor, the first to use a revolutionary technology from Oracle referred to as Software in Silicon.
Software in Silicon technology is a breakthrough in microprocessor and server design, enabling databases and applications to run faster and with unprecedented security and reliability. The Silicon Secured Memory feature of Oracle’s SPARC M7 processor provides the capability of detecting and preventing invalid operations to application data, through hardware monitoring of software access to memory. This can stop malware from exploiting software vulnerabilities, such as buffer overflows. The hardware approach of Silicon Secured Memory is much faster than traditional software-based detection tools, meaning that security checks can be done in production without significant impact to performance. In addition, each processor core contains the fastest cryptographic acceleration in the industry, allowing IT organizations to deliver end-to- end data encryption and secure transactions with near-zero performance impact. In summary: you can easily activate data protection and encryption security, by default, without additional hardware investment.
In-memory Query Acceleration is another unique Software in Silicon feature in SPARC M7-based servers. It is implemented through accelerators specifically designed into the chip’s silicon to handle SQL primitives, such as those used by Oracle Database In- Memory in Oracle Database 12c. The accelerators operate on data at full memory speeds, taking advantage of the very high memory bandwidth of the processor.
[themify_button bgcolor=”green” nofollow=”no” link=”https://docs.oracle.com/cd/E54983_01/” color=”#000000″]Download SPARC T7-2 Server Documentation PDF’s Here[/themify_button]
Brand: | Oracle / Sun Microsystems |
Condition: | Refurbished and new (limited availability) |
Availability: | Contact |
Shipping Area: | Worldwide to most countries |
Shipping Method: | Fedex (most orders), UPS, DHL, Freight Courier |
Price: | Please use the quote form above for quick pricing |
Payment: | Credit Card, Check, Net Terms (oac), Wire Transfer (required for international orders) |
Guarantee: | All items are tested by Oracle trained technicians & backed by a 100% warranty |
Questions? | Don’t hesitate to contact us with any questions regarding compatibility or other product info and requests. Our website represents only a fraction of our full inventory. Please reach out with your full requirements |
Oracle Sun SPARC T7-2 Server Processor | ||||||||||||||||||||||||||||
Number | Two SPARC M7 32-Core 4.133GHz processors | |||||||||||||||||||||||||||
CPUs |
|
|||||||||||||||||||||||||||
Cache memory | Level 1: 16KB instruction and 16 KB data per core, Level 2: 256 KB L2 I$ per four cores, 256 KB L2 D$ per core pair, Level 3: 64 MB L3$ on chip | |||||||||||||||||||||||||||
Sun SPARC T7-2 Server Main Memory | ||||||||||||||||||||||||||||
Capacities |
|
|||||||||||||||||||||||||||
Standard Integrated Interfaces | ||||||||||||||||||||||||||||
Network | 4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating | |||||||||||||||||||||||||||
Network Management | One dedicated 10/100Base-T RJ-45 port Ethernet port | |||||||||||||||||||||||||||
Serial Management | One dedicated RJ-45 port | |||||||||||||||||||||||||||
Remote Management | Onboard service processor, running Integrated Lights Out Manager (ILOM) | |||||||||||||||||||||||||||
Graphics | Two DB-15 VGA ports (one front, one rear) | |||||||||||||||||||||||||||
USB |
Front: 2 USB 2.0 Ports Rear: 2 USB 3.0 Ports Internal: 1 USB 3.0 Port |
|||||||||||||||||||||||||||
PCI Expansion Slots |
|
|||||||||||||||||||||||||||
Oracle Sun SPARC T7-2 Server Internal Mass Storage | ||||||||||||||||||||||||||||
Disks |
|
|||||||||||||||||||||||||||
DVD-ROM | One Slimline SATA DVD +/-RW | |||||||||||||||||||||||||||
Oracle Sun SPARC T7-2 Server Power Supplies | ||||||||||||||||||||||||||||
2 × 2000 Watt, hot-swappable, 1+1 redundant power supply units (PSU) | ||||||||||||||||||||||||||||
Environment | ||||||||||||||||||||||||||||
Input Voltage | 200 – 240 VAC, 50-60Hz | |||||||||||||||||||||||||||
Input Current | 13.65A @ 200 VAC (max) | |||||||||||||||||||||||||||
Input Power | 2730W @ 200 VAC (max) | |||||||||||||||||||||||||||
Maximum Heat Dissipation | 9,317 BTU/hr, 9830 KJ/hr | |||||||||||||||||||||||||||
Power Consumption | Online power calculator | |||||||||||||||||||||||||||
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -40° C to 65° C (-40° F to 149° F) |
|||||||||||||||||||||||||||
Humidity |
Operating: 10% to 90% relative humidity noncondensing, 27° C (81° F) maximum wet bulb Nonoperating: Up to 93% relative humidity noncondensing, 38° C (100° F) maximum wet bulb |
|||||||||||||||||||||||||||
Altitude |
Operating: 0m to 3,000m (0 ft. to 9,840 ft), maximum ambient temperature is derated by 1° C for every 300m above 900m (1.8° F for every 1000ft) Nonoperating: 0m to 12,000m ( 0 ft. to 39,370 ft.) |
|||||||||||||||||||||||||||
Acoustic Noise |
Operating/Idling: 67.8 dBA / 80.4 dBA (LwAd, 1B = 10dB) Operating/Idling: 7.7 B / 8.9 B (LpAm, bystander positions) |
|||||||||||||||||||||||||||
Regulations Meets or exceeds the following requirements: |
||||||||||||||||||||||||||||
Safety | UL/CSA 60950-1, EN 60950-1 CB Scheme with all country deviations | |||||||||||||||||||||||||||
EMI/EMC | FCC 47 CFR 15, ICES-003, EN 55022, EN61000-3-2, EN61000-3-3 | |||||||||||||||||||||||||||
Immunity | EN 55024 | |||||||||||||||||||||||||||
Certifications | North American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan) | |||||||||||||||||||||||||||
European Union Directives | Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and | |||||||||||||||||||||||||||
Oracle T7-2 Server Dimensions and Weight | ||||||||||||||||||||||||||||
Height | 129.8 mm (5.11 in.), 3U | |||||||||||||||||||||||||||
Width | 436.5 mm (17.185 in.) | |||||||||||||||||||||||||||
Depth | 752.5 mm (29.63 in.) | |||||||||||||||||||||||||||
Weight | Max: 37.2 kg (82 lbs) max, without rackmount kit | |||||||||||||||||||||||||||
Clearance and Service Access | ||||||||||||||||||||||||||||
Front | 914.4 mm (36 in.) | |||||||||||||||||||||||||||
Rear | 914.4 mm (36 in.) |
Batteries | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 371-2210 [C] | 3V Lithium Coin Cell Battery | n/a |
Oracle Sun SPARC T7-2 Server CPU Module | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7097099 | 32-Core 4.133GHz CPU Mezzanine | n/a | |
n/a | 7310197 | 32-Core 4.133GHz CPU Mezzanine | n/a | |
n/a | 7315604 | 32-Core 4.133GHz CPU Mezzanine | n/a |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7102870 | 7039999 [C] | MPO to MPO High Bandwidth QSFP Optical Cable, 20M | n/a | |
7102871 | 7040001 [C] | MPO to MPO High Bandwidth QSFP Optical Cable, 50M | n/a | |
7105206 | 7063852 [C] | InfiniBand Cable, QSFP, Optical, MPO to MPO, 100M | n/a | |
7110923 | 7098473 [F] | 38-Pin Mini SAS-3 Cable, SFF-8643 to SFF-8643, 460mm | n/a | |
X2121A-1M-N | 530-4444 [C] | 10Gbps QSFP to QSFP Cable, 1m | n/a | |
X2121A-3M-N | 530-4445 [C] | 10Gbps QSFP to QSFP Cable, 3m | n/a | |
X2121A-5M-N | 530-4446 [C] | 10Gbps QSFP to QSFP Cable, 5m | n/a | |
X2125A-1M-N | 530-4450 [C] | QSFP to 4× SFP+ Splitter Cable, 1m | n/a | |
X2125A-3M-N | 530-4451 [C] | QSFP to 4× SFP+ Splitter Cable, 3m | n/a | |
X2125A-5M-N | 530-4452 [C] | QSFP to 4× SFP+ Splitter Cable, 5m | n/a | |
X2130A-3M-N | 530-4442 [C] | 10Gbps SFP+ TwinX Cable, 3m | n/a | |
X2130A-5M-N | 530-4443 [C] | 10Gbps SFP+ TwinX Cable, 5m | n/a | |
X9238-1-A-N | 180-2085 [C] | IEC 320 Sheet E to IEC 320 C13 Power Jumper Cord 13A 90° 2.5M | n/a | |
n/a | 530-3100 | RJ45F to DB9F Adapter | n/a | |
n/a | 7314624 [F] | Cable Kit SKU | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a |
Oracle Sun SPARC T7-2 Server Chassis | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7074704 | Chassis Subassembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
n/a | 7303163 | G3N Chassis Subassembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7104074 | 7092757 [C] | Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 | n/a | |
n/a | 7046442 [C] | Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 | n/a |
Disk Backplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7096096 [F] | 6-Slot NVMe Backplane | n/a |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7110927 | 7302552 [C] | 1.6TB Solid State NVMe Drive Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
7110933 | 7094132 [C] | 400GB Solid State SAS Drive Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
7111103 | 7093015 [C] | 600GB – 10000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: | n/a | |
|
|
n/a | ||
|
|
n/a | ||
7111108 | 7093037 [C] | 1.2TB – 10000 RPM SAS SFF Disk Assembly w 1 bracket and 1 of the following disks: | n/a | |
|
|
n/a | ||
|
|
n/a |
T7-2 Server Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7100477 | 7070195 [C] | Quad Port GbE PCI Express 2.0 Low Profile Adapter, UTP | n/a | |
7100481 | 7070202 [C] | Dual Port GbE PCI Express 2.0 Low Profile Adapter, MMF | n/a | |
7100488 | 7070006 [C] | Dual 10-Gigabit Base-T PCI Express Gen2 | n/a | |
X1109A-Z | 7051223 [C] | Dual 10-Gigabit PCI Express Ethernet SFP+ LP | n/a | |
X2124A-N | 135-1204 [C] | 10Gb/Sec QDR InfiniBand / 40Gb/Sec Ethernet QSFP Transceiver | n/a | |
X2129A-N | 530-4449 [C] | 10Gb/Sec Short Wave SFP+ Transceiver | n/a | |
X5562A-Z | 135-1205 [C] | 10Gb/Sec Long Wave SFP+ Transceiver | n/a |
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 541-3539 [C] | 92mm Fan Module | n/a | |
n/a | 7093647 | Grey Plastic Air Divider w/ Fault Remind Button | n/a | |
n/a | 7095079 [F] | Fan Cage Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
n/a | 7303158 [F] | Fan Cage Assembly | n/a | |
|
|
n/a | ||
|
|
n/a |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7101674 | 7023303 [C] | Dual 16Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter, QLogic | n/a | |
7101676 | 7023325 [C] | Pair of 16Gbps Short Wave SFP+ | n/a | |
|
|
n/a | ||
7101678 | 7023315 [C] | Pair of 10Gbps Short Wave SFP+ | n/a | |
|
|
n/a | ||
7101684 | 7023036 [C] | Dual 16Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter, Emulex | n/a | |
7101686 | 7023059 [C] | Pair of 16Gbps Short Wave SFP+ | n/a | |
|
|
n/a | ||
SG-XPCIE2FC-EM8-N | 7053434 [C] | 8Gigabit/Sec PCI Express Dual FC Host Adapter | n/a | |
SG-XPCIE2FC-QF8-N | 371-4325 [C] | 8Gigabit/Sec PCI Express Dual FC Host Adapter | n/a |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7064634 [F] | 8-Port PCI Express Switch | n/a | |
|
|
n/a |
Oracle Sun SPARC T7-2 Server Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7107207 | 7082850 [C] | 16GB Registered DDR4-2133 DIMM | n/a | |
7107209 | 7082851 [C] | 32GB Load Reduced DDR4-2133 DIMM | n/a | |
n/a | 7074618 [C] | 2GB Embedded USB | n/a | |
n/a | 7092877 | USB T10 Torx Thumbscrew, M3 0.5 x 6mm | n/a | |
n/a | 7319165 [F] | Memory Riser Assembly | n/a | |
|
|
n/a | ||
|
|
n/a |
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7049297 [C] | A263 2000W AC Input Power Supply | n/a | |
n/a | 7300803 [F] | Power Supply Backplane Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
n/a | 7303476 [F] | Power Distribution Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
n/a | 7317314 [F] | Power Supply Backplane Assembly | n/a | |
|
|
n/a | ||
|
|
n/a |
T7-2 Server Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
XSR-JUMP-1MC13-N | 7015399 [C] | 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M | n/a | |
XSR-JUMP-2MC13-N | 7015400 [C] | 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M | n/a | |
n/a | 371-4791 [C] | Tool-less Slide Rail Rack Mount Kit | n/a | |
n/a | 371-4812 [C] | Cable Management Arm | n/a |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7302240 [C] | Tray-Load SATA DVD-Writer/CD-Writer | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
n/a | 7314403 [C] | Tray-Load DVD Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a |
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
7110119 | 7085208 [C] | 8-Port 12Gbps SAS PCI Express HBA | n/a | |
7110865 | 7307468 [C] | 1.6TB Flash Accelerator F160 NVMe Card w/ LP Bracket (B1 Silicon) | n/a |
System Board | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7315607 [F] | System Board Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
n/a | 7318240 [F] | System Board Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
n/a | 7318270 [F] | System Board Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a | ||
|
|
n/a |
System Service Processor | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | Previous Part # |
|
n/a | 7306978 [F] | Service Processor Assembly | n/a | |
|
|
n/a | ||
|
|
n/a | ||
n/a | 7319380 [F] | Service Processor Assembly | n/a | |
|
|
n/a | ||
|
|
n/a |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?