Oracle Sun M5000Servers Overview Guide | HTML | |
Oracle Sun M5000Servers Site Planning Guide | HTML | |
Oracle Sun M5000Servers Safety and Compliance Guide | HTML | |
Oracle Sun M5000Servers Getting Started Guide | HTML | |
SPARC Enterprise M5000 Server Unpacking Guide | ||
SPARC Enterprise Sun Rack 1000/900/II Equipment Rack Mounting Guide | HTML | |
Oracle Sun M5000Servers Installation Guide | ||
Oracle Sun M5000Servers Service Manual |
SPARC Enterprise M5000 Server – Software Documentation
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Product Notes for XCP Version 1115 | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Product Notes for XCP Version 1112 | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Product Notes for XCP Version 1101 | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Product Notes for XCP Version 1100 | HTML | |
Sun Oracle Sun M5000Servers Product Notes for XCP Version 1092 | HTML | |
Sun Oracle Sun M5000Servers Product Notes for XCP Version 1091 | HTML | |
Sun Oracle Sun M5000Servers Product Notes for XCP Version 1090 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1081 | ||
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1080 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1071 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1060 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1050 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1041 | HTML | |
Sun Oracle Sun M5000Servers Product Notes For XCP Version 1040 | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide | ||
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual for XCP Version 1101 | ||
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual for XCP Version 1100 | ||
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual: XSCF Control Package (XCP) 109x | ||
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual: XSCF Control Package (XCP) 1080 | ||
Sun SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF Reference Manual: XSCF Control Package (XCP) 107x | ||
Sun SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF Reference Manual: XSCF Control Package (XCP) 106x | ||
Sun SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF Reference Manual: XSCF Control Package (XCP) 105x | ||
SPARC Enterprise M4000/M5000/M8000/M9000 Servers Capacity on Demand (COD) User’s Guide | HTML | |
SPARC Enterprise M4000/M5000/M8000/M9000 Servers Dynamic Reconfiguration (DR) User’s Guide | HTML | |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Glossary | HTML |
SPARC Enterprise M5000 Server – X-Option Documentation
SPARC Enterprise M4000/M5000/M8000/M9000 Servers CPU Upgrade Guide | ||
Memory Board Guide | ||
CPU Module Guide | ||
I/O Unit Guide | ||
Fan Backplane Guide |
Related Product Documentation
External I/O Expansion Unit Documentation | LIBRARY | |
Sun Management Center 4.0 Documentation | LIBRARY | |
Sun Management Center 3.6 Documentation | LIBRARY |
M5000 Processor | |
Number | Up to 8 CPUS 2 per System Board, up to 4 System Boards SPARC64 VI: Up to 16 Cores SPARC64 VII: Up to 32 Cores |
Architecture |
SPARC64 VI: 2.15GHz Dual Core processors, SPARC V9, ECC Protected SPARC64 VII: 2.4GHz Quad Core processors, SPARC V9, ECC Protected SPARC64 VII: 2.53GHz Quad Core processors, SPARC V9, ECC Protected |
Cache memory |
SPARC64 VI: 5MB Shared Level 2 on Chip Cache per Processor, 128KB I-Cache and 128KB D-Cache Level 1 per Core SPARC64 VII: 5MB Shared Level 2 on Chip Cache per Processor, 64KB I-Cache and 64KB D-Cache Level 1 per Core |
Main Memory | |
Capacities | 16GB (using 1GB DDR2 DIMMS) to 512GB (using 8GB DDR2 DIMMs), 8 slots per board, 8 memory boards per system. |
Standard Interfaces | |
Ethernet | 2 × Gigabit Ethernet ports, also 2 × 10/100 ethernet ports for accessing CLI and browser based interface on Extended System Control Facility (XSCF) |
PCI-X / PCI-Express | 1 × PCI-X Slot, 4 × PCI-Express Slots per I/O tray |
Serial | 1 RJ-45 – on XSCF to access CLI |
USB | One port on XSCF that field engineer can use to download hardware information |
Internal Mass Storage | |
Disks | Up to 4 internal 73GB SAS Disk Drives |
DVD-ROM | 1 CD-RW / DVD-RW |
Tape | DAT72 Tape Drive (optional) |
Power Supplies | |
Type | 4× 100-240 VAC, 2000W, 1-phase (50-60Hz), 12 amp per power cord, 2 – 4 power cords (2 + 2 redundant, second and fourth power supplies are redundant at 200 VAC) |
Output | 4590 Watts (4 power cords) |
Environment | |
AC Power | 100-240VAC |
Power Draw | 4590 Watts (4 power cords) |
Volt Ampere | 3815 VA |
Input power | 100 – 127 VAC 200 – 240 VAC |
Maximum Current | 48A at 100 127 VAC, 12A / cord 24A at 200 240 VAC, 12A / cord |
Heat output | 12754 BTU/hr (13457 kJ/hr) – 4 CPU modules, 256GB memory |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) * Nonoperating: -20° C to 60° C (-4° F to 140° F) * Optimal: 21° C to 23° C (70° F to 74° F) x2 |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing Nonoperating: Up to 93% RElative humidity, noncondensing Optimal:45% to 50% relative humidity, noncondensing |
Altitude |
Operating: Up to 3000m (10000 ft) Nonoperating: 12000m (39,370 ft) |
* – derated 2° C for every 1km up to 3km | |
Regulations Meets or exceeds the following requirements: |
|
RoHS Compliance Level | RoHS:YL, WEEE and Chinese RoHS |
Safety | CSA/UL-60950, EN60950, IEC950 CB Scheme with all national deviations |
Ergonomics | GS |
RFI/EMI | EN55022/CISPR22 Class-A, FCC CFR47 Part 15 Class A, EN61000-3-2, EN61000-3-3 |
Immunity | EN55024, EN61000-4-2, -4-3, -4-5, -4-6, -4-8, -4-11 |
Regulatory Markings | CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL |
Dimensions and Weights | |
Height | 44.02cm (17.33 in) |
Width | 44.4cm (17.48 in) |
Depth | 81cm (31.9 in) |
Weight | 125kg (275 lbs) |
Backplane/Centerplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-0493 | Power and I/O Backplane, RoHS:Y | ||
n/a | 541-1145 | DVD Backplane, RoHS:Y | ||
n/a | 541-1146 | DAT Backplane, RoHS:Y | ||
n/a | 541-3099 | Fan Backplane (172mm Fans), RoHS:YL |
CPU Module | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SELX1A1Z | 375-3477 | 2 × SPARC64 VI 2.1GHz CPU Module, RoHS:YL | ||
SELX1C1Z | 371-4615 | 2 × SPARC64 VII 2.53GHz CPU Module, RoHS:Y | ||
SELX1B1Z | 375-3568 | 2 × SPARC64 VII 2.4GHz CPU Module, RoHS:YL |
Cables | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SELX9P11Z | 180-2005 | AC Input Power Cord, 20A, Americas Domestic, NEMA L6-20P to IEC320-C19, 4m, RoHS:Y | ||
SELX9P21Z | 180-2004 | AC Input Power Cord, 16A, International, IEC309 to IEC320-C19, 4m, RoHS:Y | ||
SELX9P31Z | 180-2097 | M4000/M5000 2.5 Meter Rack Jumper Power Cable, RoHS:Y | ||
SELX9P41Z | n/a | AC Input Cord, USA, Canada, IEC 320 C19 to NEMA 5-15P, 2.5 Meter | ||
SELX9P51Z | 180-2309 | Power Cord Jumper, 2.5M 13 Amp, IEC60320-C14 plug to IEC60320-C19 connector, RoHS:Y | ||
SELX9P61Z | 180-2421 | IEC 320 C19 to IRAM 2073, 16A/250V, 4.0M, Black, RoHS:Y | ||
SELX9P71Z | 180-2099 | Power Cord Jumper, 3.5M 20 Amp, IEC 320 C19 to IEC 320 Sheet I, RoHS:Y | ||
SENX8FC1Z | 537-1100 | Fibre Channel Optical Cable 10M, RoHS:Y | ||
SENX8FC2Z | 537-1070 | Fibre Channel Optical Cable 25M, RoHS:Y | ||
n/a | 530-3100 | RJ45F to DB9F Adapter, RoHS:Y | ||
n/a | 530-3885 | RJ45F to DB9F Adapter, RoHS:Y | ||
n/a | 537-1077 | Copper Cable 3M (for External I/O Expansion Unit), RoHS:Y |
Communication | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X1355A-2 | 371-0982 | 2M, 80-Pin, 4-Port, DB37, RS449 Breakout Cable,RoHS:Y | ||
375-3296 | Quad Port High Speed Serial Interface PCI-X (HSI/U), RoHS:Y | |||
X2156A-2 | 375-3420 | Serial Asynchronous Interface PCI (SAI/P) 3.0, RoHS:Y | ||
X4237A | 375-3606 | Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express, RoHS:Y | ||
X6000A | 375-3424 | PCI Express Sun Crypto Accelerator 6000, RoHS:Y |
Disk Backplane | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-0845 | Disk Backplane Assembly, RoHS:Y |
Disks | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SELX3C12Z | 541-4283 | 146GB 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
SELX3E11Z | 540-7903 | 300GB – 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks:, RoHS:Y | ||
|
|
|||
|
|
|||
SEPX3A11Z | 540-7307 | 73GB 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
SEPX3C11Z | 540-7777 | 146GB 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
n/a | 540-7151 | 146GB – 10000 RPM SAS, Disk Assembly with 1 bracket and 1 of the following disks and brackets, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Ethernet | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIEFCOE2-Q-SR | 375-3681 | Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA – SR, RoHS:Y | ||
SG-XPCIEFCOE2-Q-TA | 375-3682 | Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA – Direct Attach, RoHS:Y | ||
X1027A-Z | 501-7283 | PCI Express Dual 10-Gigabit Ethernet Fiber, RoHS:Y | ||
X1106A-Z | 375-3585 | Intel PRO/10GbE-SR x8 PCI Express Low Profile Bracket, RoHS:Y | ||
X1107A-Z | 375-3586 | Intel PRO/10GbE-SR x8 PCI Express Low Profile Bracket, RoHS:Y | ||
X4447A-Z | 511-1422 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
560-2884 | Ship Kit for Gigabit Ethernet options | |||
|
|
|||
X5558A | 375-3301 | 10Gb/sec XFP Optical Transceiver Short Range (SR), RoHS:YL | ||
X5560A-Z | 375-3495 | 10Gb/sec XFP Optical Transceiver Long Range (LR), RoHS:Y | ||
X7280A-2 | 371-0905 | PCI Express Dual Gigabit Ethernet UTP, RoHS:Y | ||
X7281A-2 | 371-0904 | PCI Express Dual Gigabit Ethernet MMF, RoHS:Y | ||
n/a | 501-7606 | PCI Express Quad Gigabit Ethernet UTP, RoHS:Y | ||
|
|
|||
|
|
Fan | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-3447 | 172mm Fan Module, Fan_A, RoHS:Y |
Fibre Channel | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCI1FC-EM4-Z | 375-3398 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI1FC-QF4 | 375-3354 | 4Gb PCI-X Single FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-EM4-Z | 375-3399 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCI2FC-QF4 | 375-3294 | 4Gb PCI-X Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-EM4 | 375-3396 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-EM8-Z | 371-4295 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF4 | 375-3355 | 4Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE1FC-QF8-Z | 371-4324 | 8Gigabit/Sec PCI Express Single FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM4 | 375-3397 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-EM8-Z | 371-4306 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF4 | 375-3356 | 4Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y | ||
SG-XPCIE2FC-QF8-Z | 371-4325 | 8Gigabit/Sec PCI Express Dual FC Host Adapter, RoHS:Y |
Graphics | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
X3000A | 375-3545 | XVR-300 x8 Graphics Accelerator, RoHS:Y | ||
530-3474 | DVI-A(M) to HD15F Adapter, 49mm, RoHS:Y | |||
530-3998 | DMS-59 to Dual DVI-I Cable, 215mm, RoHS:Y | |||
X3777 | 375-3433 | XVR-200 Graphics Accelerator, RoHS:Y | ||
X7296A | 375-3290 | XVR-100 Graphics Accelerator (64MB), RoHS:Y |
I/O | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SEFX61Z | 541-0929 | PCI Express Cassette, RoHS:Y | ||
541-0933 | PCI-X Cassette, RoHS:Y | |||
541-2240 | I/O Unit (IOU), RoHS:YL | |||
|
|
|||
|
|
|||
SELX8LK1Z | 596-7158 | Copper Link Card Kit w/ 2 × Cards & 4M Cable | ||
|
|
|||
|
|
|||
|
|
|||
SENX8LK2Z | 596-6258 | Fibre Link Card Kit w/ 2 × Cards & 2 × 10M Cables (for External I/O Expansion Unit), RoHS:Y | ||
|
|
|||
|
|
|||
SENX8LK3Z | 596-6228 | Fibre Link Card Kit w/ 2 × Cards & 2 × 25M Cables (for External I/O Expansion Unit), RoHS:Y | ||
|
|
|||
|
|
|||
XMP10C-S | 596-5630 | Copper Link Card Kit w/ 2 × Cards & 3M Cable (for External I/O Expansion Unit), RoHS:Y | ||
|
|
|||
|
|
|||
|
|
Memory | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SELX2B2Z | 8 × 2GB Memory Module, RoHS:YL | |||
371-4236 | 2GB DDR2-667 1-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2C1Z | 8 × 4GB Memory Module, RoHS:YL | |||
371-1901 | 4GB DDR2-667 2-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2D1Z | 8 × 8GB Memory Module, RoHS:YL | |||
371-4476 | 8GB DDR2-667 2-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2F2Z | 4 × 2GB Memory Module, RoHS:YL | |||
371-4236 | 2GB DDR2-667 1-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2FX2Z | 4 × 2GB Memory Expansion X-Option, RoHS:YL | |||
371-4236 | 2GB DDR2-667 1-Rank DIMM, RoHS:Y | |||
SELX2A1Z | 8 × 1GB Memory Module, RoHS:YL | |||
371-1899 | 1GB DDR2-533/DDR2-667 1-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2B1Z | 8 × 2GB Memory Module, RoHS:YL | |||
371-1900 | 2GB DDR2-533 / DDR2-667 2-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2E1Z | 4 × 1GB Memory Module, RoHS:YL | |||
371-1899 | 1GB DDR2-533/DDR2-667 1-Rank DIMM, RoHS:Y | |||
541-0545 | Memory Board, RoHS:YL | |||
SELX2EX1Z | 4 × 1GB Memory Expansion X-option, RoHS:YL | |||
371-1899 | 1GB DDR2-533/DDR2-667 1-Rank DIMM, RoHS:Y |
Miscellaneous | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SEFX9FL1Z | 565-1900 | M5000 Air Filter Kit, RoHS:YL | ||
|
|
|||
|
|
|||
n/a | 541-0850 | Operator Panel, RoHS:Y |
Power | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 300-2009 | 1.2V DC-DC Converter, DDC_A, RoHS:Y | ||
n/a | 300-2010 | 3.3V DC-DC Converter, DDC_B, RoHS:Y | ||
n/a | 300-2011 | Type A202 AC Input Power Supply, RoHS:YL | ||
n/a | 371-4650 | Energy Storage Module (ESM), RoHS:Y | ||
n/a | 501-7647 | IOB DC-DC Converter Riser, DDCR, RoHS:Y |
Rack | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
XRACK-EXTEND38RU | 341-3043 | 38RU Rack Extension, RoHS:Y | ||
XRACK-EXTEND42RU | 341-3044 | 42RU Rack Extension, RoHS:Y | ||
n/a | 371-0095 | M5000 Rack Mount Kit, RoHS:Y |
Removable Media | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SELX9DT1Z | 263-3537 | DAT Removal Tool, RoHS:Y | ||
541-0846 | DAT72 Tape Drive Assembly, RoHS:Y | |||
541-3852 | DAT72 Tape Drive Assembly, RoHS:Y | |||
n/a | F541-0846 | DAT72 Tape Drive Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
n/a | F541-0847 | DVD Assembly, RoHS:Y | ||
|
|
|||
|
|
|||
n/a | F541-3451 | DVD Assembly, RoHS:Y | ||
|
|
|||
n/a | F541-3852 | DAT72 Tape Drive Assembly, RoHS:Y | ||
|
|
|||
|
|
SCSI | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
SG-XPCIE2SCSIU320Z | 375-3357 | Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y | ||
SG-XPCIE8SAS-E-Z | 375-3487 | PCI Express 8-Port Host Adapter, RoHS:Y | ||
SGXPCIESAS-R-EXT-Z | 371-3253 | Lithium Ion Battery Module | ||
375-3537 | 8-Port SAS RAID External HBA, RoHS:Y | |||
XTA-FAS-S3IE96GB | 541-3731 | 96GB PCI Express Flash Accelerator F20 SAS HBA, RoHS:Y | ||
|
|
|||
|
|
|||
|
|
|||
SGXPCI2SCSILM320-Z | 375-3365 | PCI Dual Ultra320 SCSI Adapter, RoHS:YL |
System Board | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-0478 | Motherboard Cage (TMOBO/MBU_B) includes motherboard 501-7670, RoHS:Y | ||
|
|
|||
|
|
System Service Processor | ||||
---|---|---|---|---|
Option # | Manufacturing Part # |
Description | ||
n/a | 541-0481 | eXtended System Control Facility Unit, XSCFU, RoHS:YL |
Industry Leading Quality, Support and Integrity
Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.
Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.
Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.
Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.